Yazar "Abou Ayash, Samir" seçeneğine göre listele
Listeleniyor 1 - 4 / 4
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Effect of intraoral scanner and fixed partial denture situation on the scan accuracy of multiple implants: an in vitro study(Wiley, 2023) Abou Ayash, Samir; Yılmaz, Burak; Mathey, Amber; Gaeumann, Fabio; Mathey, Ayşe; Dönmez, Mustafa BorgaBackgroundAccuracy of intraoral implant scans may be affected by the region of the implant and the type of the intraoral scanner (IOSs). However, there is limited knowledge on the scan accuracy of multiple implants placed for an implant-supported fixed partial denture (FPD) in different partially edentulous situations when digitized by using different IOSs. PurposeTo investigate the effect of IOS and FPD situation on the scan accuracy of two implants when partial-arch scans were performed. Materials and MethodsTissue level implants were placed in 3 maxillary models with implant spaces either at right first premolar and right first molar sites (Model 1, 3-unit FPD), at right canine and right first molar sites (Model 2, 4-unit FPD), or at lateral incisor sites (Model 3, 4-unit FPD). Reference standard tessellation language (STL) files of the models were generated by using an optical scanner (ATOS Capsule 200MV120). Two IOSs (CEREC Primescan [CP] and TRIOS 3 [TR]) were used to perform partial-arch scans (test-scans) of each model (n = 14), which were exported in STL format. A metrology-grade analysis software (GOM Inspect 2018) was used to superimpose test-scan STLs over the reference STL to calculate 3D distance, inter-implant distance, and angular (mesiodistal and buccopalatal) deviations. Trueness and precision analyses were performed by using bootstrap analysis of variance followed by Welch tests with Holm correction (alpha = 0.05). ResultsTrueness of the scans was affected by IOS and FPD situation when 3D distance deviations were considered, while inter-implant distance, mesiodistal angular, and buccopalatal angular deviations were only affected by the FPD situation (p < 0.001). Scan precision was affected by the interaction between the IOSs and the FPD situation when 3D distance and buccopalatal angular deviations were concerned, while IOSs and FPD situation were effective when all deviations were concerned (p <= 0.001). When 3D distance deviations were considered, CP scans had higher accuracy TR scans in Models 1 and 3 (p <= 0.002), and the Model 1 scans had the highest accuracy (p < 0.001). When inter-implant distance deviations were considered, Model 1 scans had the highest accuracy with CP and higher accuracy than Model 2 when TR was used (p <= 0.030). When mesiodistal angular deviations were considered, Model 1 scans had the highest accuracy (p <= 0.040). When buccopalatal angular deviations were considered, Model 1 scans had the highest accuracy among models when CP was used (p <= 0.020). ConclusionsPosterior 3-unit fixed partial denture implant scans, CP scans, and combination of these two factors had accuracy either similar to or better than their tested counterparts.Öğe Fatigue behavior of implant-supported cantilevered prostheses in recently introduced CAD-CAM polymers: An in vitro study(Elsevier Inc., 2024) Dönmez, Mustafa Borga; Çakmak, Gülce; Güven, Mehmet Esad; Dede, Doğu Ömür; Abou Ayash, Samir; Yılmaz, BurakStatement of problem: Cantilevered complete arch implant-supported prostheses are commonly fabricated from zirconia and more recently from strength gradient zirconia. Different polymer-based materials indicated for definitive fixed prostheses that could be used with additive or subtractive manufacturing have also been marketed recently. However, knowledge on the long-term fatigue behavior of cantilevered implant-supported prostheses made from these polymer-based materials and strength gradient zirconia is lacking. Purpose: The purpose of this in vitro study was to evaluate the fatigue behavior of implant-supported cantilevered prostheses of recently introduced computer-aided design and computer-aided manufacturing polymers and zirconia. Material and methods: A master standard tessellation language file of a 9×11×20-mm specimen with a titanium base (Ti-base) space that represented an implant-supported cantilevered prosthesis was used to fabricate specimens from additively manufactured interim resin (AM), polymethyl methacrylate (SM-PM), nanographene-reinforced polymethyl methacrylate (SM-GR), high-impact polymer composite resin (SM-CR), and strength gradient zirconia (SM-ZR) (n=10). Each specimen was prepared by following the respective manufacturer's recommendations, and Ti-base abutments were cemented with an autopolymerizing luting composite resin. After cementation, the specimens were mounted in a mastication simulator and subjected to 1.2 million loading cycles under 100 N at 1.5 Hz; surviving specimens were subjected to another 1.2 million loading cycles under 200 N at 1.5 Hz. The load was applied to the cantilever extension, 12-mm from the clamp of the mastication simulator. The Kaplan–Meier survival analysis and Cox proportional hazards model were used to evaluate the data (α=.05). Results: Significant differences in survival rate and hazard ratio were observed among materials (P<.001). Among tested materials, SM-ZR had the highest and AM had the lowest survival rate (P≤.031). All materials had a significantly higher hazard ratio than SM-ZR (P≤.011) in the increasing order of SM-GR, SM-PM, SM-CR, and AM. Conclusions: SM-ZR had the highest survival rate with no failed specimens. Even though most of the tested polymer-based materials failed during cyclic loading, these failures were commonly observed during the second 1.2 million loading cycles with 200 N. All materials had a higher hazard ratio than SM-ZR. © 2024 The AuthorsÖğe Fracture resistance of additively or subtractively manufactured resin-based definitive crowns: Effect of restorative material, resin cement, and cyclic loading(Elsevier Inc., 2024) Çakmak, Gülce; Dönmez, Mustafa Borga; Molinero-Mourelle, Pedro; Kahveci, Çiğdem; Abou Ayash, Samir; Peutzfeldt, Anne; Yılmaz, BurakObjective: To evaluate how restorative material, resin cement, and cyclic loading affect the fracture resistance of resin-based crowns fabricated by using additive or subtractive manufacturing. Methods: A right first molar crown standard tessellation language (STL) file was used to fabricate 120 crowns from one subtractively manufactured polymer-infiltrated ceramic network (SM) and two additively manufactured resin composites (AM-B and AM-S) (N = 40). These crowns were randomly divided into 4 groups within each material according to the dual-polymerizing resin cement to be used (RX and PN) and the aging condition (n = 10). After cementation, the crowns without cyclic loading were subjected to fracture testing, while the others were first cyclically loaded (1.7 Hz, 1.2 million cycles, and 49-N load) and then subjected to fracture testing. Data were analyzed with generalized linear model analysis (α = .05). Results: Fracture resistance of the crowns was affected by material, resin cement, and cyclic loading (P ≤ .030). However, none of the interactions significantly affected fracture resistance of tested crowns (P ≥ .140). Among tested materials, SM had the highest fracture resistance, whereas AM-B had the lowest (P ≤ .025). RX led to higher fracture resistance, and cyclic loading decreased the fracture resistance (P ≤ .026). Significance: Tested materials can be considered reliable in terms of fracture resistance in short- or mid-term (5 years of intraoral simulation) when used for single molar crowns with 2 mm occlusal thickness. In the long term, polymer-infiltrated ceramic network crowns cemented with RelyX Universal may provide promising results and be less prone to complications considering higher fracture resistance values obtained. © 2024 The AuthorsÖğe In vitro scan accuracy and time efficiency in various implant-supported fixed partial denture situations(Elsevier, 2022) Abou Ayash, Samir; Mathey, Amber; Gäumann, Fabio; Mathey, Ayşe; Dönmez, Mustafa Borga; Yılmaz, BurakIn vitro scan accuracy and time efficiency in various implant-supported fixed partial denture situations