Yazar "Cuellar, Alfonso Rodriguez" seçeneğine göre listele
Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Color and translucency of milled polymethyl methacrylate crowns on non-tooth-colored interim abutments with different surface treatments(2022) Çakmak, Gülce; Cuellar, Alfonso Rodriguez; Treviño Santos, Alejandro; Johnston, William M; Dönmez, Mustafa Borga; Yılmaz, BurakStatement of problem: The interim rehabilitation of implants has become a necessity, particularly for those placed in the esthetic regions. However, the optical properties of computer-aided design and computer-aided manufacturing (CAD-CAM) polymethyl methacrylate (PMMA) crowns on interim abutments with different surface treatments are unclear. Purpose: The purpose of this in vitro study was to investigate the color and translucency of CAD-CAM PMMA crowns when different surface treatments were used on titanium interim abutments. Material and methods: A maxillary dentate stone cast with a narrow-diameter implant analog at the left lateral incisor site was used. Three titanium interim abutments (blue) were divided into 3 groups according to the surface treatment they received: control (steam cleaning), opaqued (120-?m Al2O3 airborne-particle abrasion and opaque application), and airborne-particle abraded (120-?m Al2O3). Thirty PMMA crowns (A2 shade) were milled (n=10). The color coordinates of the crown-interim abutment pairs and a shade tab (A2) were measured by using a colorimeter. The color differences (?E00) between the crowns and the shade tab and the relative translucency parameter (RTP) values of the crowns were calculated by using the CIEDE2000 formula. One-way ANOVA was used to analyze the ?E00 and RTP values with subsequent Tukey honestly significant difference tests (?=.05). Results: The abutment surface treatment significantly affected the ?E00 of interim crowns from the shade tab (P<.001), but no significant effect was found on RTP (P=.26). The control group had the highest ?E00 from the shade tab (P?.011). No significant difference (P=.14) was found between the opaqued and the ?E00 of the airborne-particle abraded groups from the shade tab. Conclusions: The surface treatments of interim abutments affected the color of CAD-CAM PMMA crowns, which differed from that of the shade tab. The color of crowns on opaqued or airborne-particle abraded interim abutments was closer to the color of the shade tab. Abutment surface treatments did not affect the translucency of crown-interim abutment pairs.Öğe Surface roughness and color stability of 3D-Printed denture base materials after simulated brushing and thermocycling(MDPI, 2022) Çakmak, Gülce; Molinero Mourelle, Pedro; De Paula, Marcella Silva; Akay, Canan; Cuellar, Alfonso Rodriguez; Dönmez, Mustafa Borga; Yılmaz, BurakThree-dimensional (3D) printing is increasingly used to fabricate denture base materials. However, information on the effect of simulated brushing and thermocycling on the surface roughness and color stability of 3D-printed denture base materials is lacking. The aim of this study was to evaluate the effect of brushing and thermocycling on the surface roughness and color stability of 3D-printed denture base materials and to compare with those of milled and heat-polymerized denture base resins. Disk-shaped specimens (Ø 10 mm × 2 mm) were prepared from 4 different denture base resins (NextDent Denture 3D+ (ND); Denturetec (SC); Polident d.o.o (PD); Promolux (CNV)) (n = 10). Surface roughness (Ra) values were measured before and after polishing with a profilometer. Initial color coordinates were measured by using a spectrophotometer after polishing. Specimens were then consecutively subjected to simulated brushing (10,000 cycles), thermocycling (10,000 cycles), and brushing (10,000 cycles) again. Ra and color coordinates were measured after each interval. Color differences (?E00) between each interval were calculated and these values were further evaluated considering previously reported perceptibility (1.72 units) and acceptability (4.08 units) thresholds. Data were analyzed with Friedman, Kruskal–Wallis, and Mann–Whitney U tests (? = 0.05). Ra (p ? 0.051) and ?E00 (p ? 0.061) values among different time intervals within each material were similar. Within each time interval, significant differences in Ra (p ? 0.002) and ?E00 values (p ? 0.001) were observed among materials. Polishing, brushing, and thermocycling resulted in acceptable surface roughness for all materials that were either similar to or below 0.2 µm. Color of ND printed resin was affected by brushing and thermocycling. All materials had acceptable color stability when reported thresholds are considered.