Yazar "Johnston, William M" seçeneğine göre listele
Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Color and translucency of milled polymethyl methacrylate crowns on non-tooth-colored interim abutments with different surface treatments(2022) Çakmak, Gülce; Cuellar, Alfonso Rodriguez; Treviño Santos, Alejandro; Johnston, William M; Dönmez, Mustafa Borga; Yılmaz, BurakStatement of problem: The interim rehabilitation of implants has become a necessity, particularly for those placed in the esthetic regions. However, the optical properties of computer-aided design and computer-aided manufacturing (CAD-CAM) polymethyl methacrylate (PMMA) crowns on interim abutments with different surface treatments are unclear. Purpose: The purpose of this in vitro study was to investigate the color and translucency of CAD-CAM PMMA crowns when different surface treatments were used on titanium interim abutments. Material and methods: A maxillary dentate stone cast with a narrow-diameter implant analog at the left lateral incisor site was used. Three titanium interim abutments (blue) were divided into 3 groups according to the surface treatment they received: control (steam cleaning), opaqued (120-?m Al2O3 airborne-particle abrasion and opaque application), and airborne-particle abraded (120-?m Al2O3). Thirty PMMA crowns (A2 shade) were milled (n=10). The color coordinates of the crown-interim abutment pairs and a shade tab (A2) were measured by using a colorimeter. The color differences (?E00) between the crowns and the shade tab and the relative translucency parameter (RTP) values of the crowns were calculated by using the CIEDE2000 formula. One-way ANOVA was used to analyze the ?E00 and RTP values with subsequent Tukey honestly significant difference tests (?=.05). Results: The abutment surface treatment significantly affected the ?E00 of interim crowns from the shade tab (P<.001), but no significant effect was found on RTP (P=.26). The control group had the highest ?E00 from the shade tab (P?.011). No significant difference (P=.14) was found between the opaqued and the ?E00 of the airborne-particle abraded groups from the shade tab. Conclusions: The surface treatments of interim abutments affected the color of CAD-CAM PMMA crowns, which differed from that of the shade tab. The color of crowns on opaqued or airborne-particle abraded interim abutments was closer to the color of the shade tab. Abutment surface treatments did not affect the translucency of crown-interim abutment pairs.