Arşiv logosu
  • English
  • Türkçe
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • DSpace İçeriği
  • Analiz
  • English
  • Türkçe
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Tambas, Makbule" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Computed tomography-guided optimization of needle insertion for combined intracavitary/interstitial brachytherapy with utrecht applicator in locally advanced cervical cancer
    (Elsevier Inc., 2021) Tambas, Makbule; Tavlı, Büşra; Bilici, Nazlı; Dizman, Aysen; Sertel, Hüseyin; Fayda, Merdan
    Purpose: There are no international guidelines for optimal needle insertion during interstitial intracavitary brachytherapy (IS-ICBT) for cervical cancer. We aimed to investigate the clinical feasibility and added value of computed tomography (CT) guidance to optimize needle insertion in IS-ICBT using the Utrecht applicator and to evaluate needle shifts. Methods and Materials: We enrolled 24 patients who were treated with IS-BT. Two CT scans each were performed for every patient: 1) after applicator insertion without needles (CTpreneedle); 2) after needle insertion (CTpostneedle). In addition to magnetic resonance imaging (MRI) after external-beam radiotherapy, CTpreneedle was used to determine optimal needle locations and insertion lengths based on applicator and organs at risk positioning on the day of treatment; CTpostneedle was used for IS-ICBT planning. The needle-channel axis was used as a reference to determine needle-shift evolution. Results: A total of 266 interstitial needles were inserted in 76 of 93 BT fractions with high intra- and interpatient variations in the number of inserted needles. Based on CTpreneedle findings, needle insertion was avoided in nine, four, two, and two patients at the first, second, third, and fourth fractions, respectively. The unloaded needle frequency was 4%. Average needle contribution to total dwell time was 37.2±19.2%. Shifting was observed in 68% of the needles (mean shift 2.0±2.3 mm), mostly in the posterior direction, and in needles with a larger insertion length. Needle reinsertion was not needed in any patient. No complication due to needle insertion was observed, except for minor vaginal bleeding in one patient after needle removal.

| İstinye Üniversitesi | Kütüphane | Açık Bilim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


İstinye Üniversitesi, İstanbul, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim