In-depth exploration of the radiation exposure to staff performing endoscopic retrograde cholangiopancreatography procedures (ERCP) through RANDO phantom and TLDs

dc.authorscopusidHüseyin Ozan Tekin / 56971130700
dc.authorwosidHüseyin Ozan Tekin / J-9611-2016
dc.contributor.authorKesmezacar, Fahrettin Fatih
dc.contributor.authorTunçman, Duygu
dc.contributor.authorNaycı, Ali Emre
dc.contributor.authorGünay, Osman
dc.contributor.authorYeyin, Nami
dc.contributor.authorÜzüm, Güngör
dc.contributor.authorDemir, Mustafa
dc.contributor.authorAkkuş, Baki
dc.contributor.authorElshami, Wiam
dc.contributor.authorAlmisned, Ghada
dc.contributor.authorTekin, Hüseyin Ozan
dc.date.accessioned2025-04-18T10:31:44Z
dc.date.available2025-04-18T10:31:44Z
dc.date.issued2024
dc.departmentİstinye Üniversitesi, Mühendislik ve Doğa Bilimleri Fakültesi, Bilgisayar Mühendisliği Bölümü
dc.description.abstractThis study provides a comprehensive evaluation of the occupational radiation exposure faced by healthcare professionals during Endoscopic Retrograde Cholangiopancreatography (ERCP) procedures. Utilizing an anthropomorphic RANDO phantom equipped with Thermoluminescent Dosimeters (TLDs), we replicated ERCP scenarios to measure radiation doses received by medical staff. The study meticulously assessed radiation exposure in various corresponding body regions typically occupied by medical staff during ERCP, with a focus on eyes, thyroid, hands, and reproductive corresponding organ regions. The findings revealed significant variations in radiation doses across different body parts, highlighting areas of higher exposure and underscoring the need for improved protective measures and procedural adjustments. The effective radiation doses were calculated using standard protocols, considering the varying levels of protection offered by lead aprons and thyroid shields. The results demonstrate the substantial radiation exposure experienced by healthcare staff, particularly in regions not adequately shielded. This study emphasizes the necessity for enhanced radiation safety protocols in clinical settings, advocating for advanced protective equipment, training in radiation safety, and the exploration of alternative imaging modalities. The findings have crucial implications for both patient and staff safety, ensuring the continued efficacy and safety of ERCP and similar interventional procedures. This research contributes significantly to the field of occupational health and safety in interventional radiology, providing vital data for the development of safer medical practices. © The Author(s) under exclusive licence to Japan Radiological Society 2024.
dc.identifier.citationKesmezacar, F. F., Tunçman, D., Nayci, A. E., Günay, O., Yeyin, N., Üzüm, G., ... & Tekin, H. O. (2024). In-depth exploration of the radiation exposure to staff performing endoscopic retrograde cholangiopancreatography procedures (ERCP) through RANDO phantom and TLDs. Japanese Journal of Radiology, 1-9.
dc.identifier.doi10.1007/s11604-024-01586-4
dc.identifier.endpage1066
dc.identifier.issn18671071
dc.identifier.issue9
dc.identifier.pmid38720059
dc.identifier.scopus2-s2.0-85192513426
dc.identifier.scopusqualityQ2
dc.identifier.startpage1058
dc.identifier.urihttp://dx.doi.org/10.1007/s11604-024-01586-4
dc.identifier.urihttps://hdl.handle.net/20.500.12713/7104
dc.identifier.volume42
dc.identifier.wosWOS:001216053800001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.indekslendigikaynakWeb of Science
dc.institutionauthorTekin, Hüseyin Ozan
dc.institutionauthoridHüseyin Ozan Tekin / 0000-0002-0997-3488
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofJapanese Journal of Radiology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectALARA
dc.subjectERCP
dc.subjectOccupational Dose
dc.subjectRadiation Protection
dc.subjectRANDO
dc.titleIn-depth exploration of the radiation exposure to staff performing endoscopic retrograde cholangiopancreatography procedures (ERCP) through RANDO phantom and TLDs
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Indepth-exploration-of-the-radiation-exposure-to-staff-performing-endoscopic-retrograde-cholangiopancreatography-procedures-ERCP-through-RANDO-phantom-and-TLDsJapanese-Journal-of-Radiology (1).pdf
Boyut:
751.18 KB
Biçim:
Adobe Portable Document Format
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: