• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace@İSÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed | DergiPark
  • TR-Dizin İndeksli Yayınlar Koleksiyonu
  • View Item
  •   DSpace@İSÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed | DergiPark
  • TR-Dizin İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Soldan sağa şantlı doğumsal kalp hastalıklı çocuklarda şant miktarı ile kardiyotrofin–1 ilişkisi

Thumbnail

View/Open

Tam Metin / Full Text (453.3Kb)

Date

2018

Author

Çetin, Benhur Şirvan
Kır, Mustafa
Ünal, Nurettin
Küme, Tuncay
Yılmaz, Nuh

Metadata

Show full item record

Citation

ÇETİN B. Ş,KIR M,ÜNAL N,KÜME T,YILMAZ N (2018). Soldan sağa şantlı doğumsal kalp hastalıklı çocuklarda şant miktarı ile kardiyotrofin–1 ilişkisi. Dokuz Eylül Üniversitesi Tıp Fakültesi Dergisi, 32(2), 123 - 130. Doi: 10.5505/deutfd.2018.25338.30074

Abstract

Amaç: Çalışmamızda çocuklarda soldan sağa şantlı doğumsal kalp hastalıklarında serum kardiyotrofin-1 (CT-1) düzeyleri ile şant miktarının karşılıklı etkileşimlerini araştırmak, bu belirtecin intrakardiyak defekt tipine göre değişimlerini incelemek amaçlanmıştır. Gereç ve Yöntem: Çalışmamızda, 1 ay–13 yaşları arasında, 45 hasta ve 23 sağlıklı çocuk incelendi. Hasta grubu içinde 19 olguda atriyal septal defekt (ASD), 17 olguda ventriküler septal defekt (VSD), 6 olguda ASD ve VSD (ASD+VSD) ve 3 olguda patent duktus arteriyozus (PDA) mevcuttu. Tüm çocuklara konvansiyonel ekokardiyografi incelemesi (iki boyutlu, M-Mode, iki boyutlu Doppler ve renkli Doppler ekokardiyografileri) yapıldı. Tüm olgulardan ekokardiyografi çalışmaları ile eş zamanlı olarak plazma BNP düzeyleri kemilüminisans ve CT-1 düzeyleri de “enzyme-linked immunosorbent assay” (ELISA) yöntemleriyle ölçüldü. Bulgular: Hasta grubunda CT-1 ile şant miktarı arasında (p<0,02, r=0,35), ASD grubunda da CT-1 ile defekt çapı arasında pozitif korelasyon saptandı (p<0,05, r=0,49). Ayrıca, geniş VSD’li olgularda CT-1 düzeyi kontrole göre yüksekti (p<0,05). Soldan-sağa şant miktarı yüksek olan grupta (pulmoner kan akımı/sistemik kan akımı: Qp/Qs >2) CT-1 ile EF ve FS arasında negatif korelasyon bulundu (p<0,001, r=0,71). Sonuç: CT-1’in soldan sağa şantlı kalp hastalıkları grubunda yükselmiş olduğu bulundu. Bunun yanı sıra intrakardiyak şantı fazla, kalp yetersizliği riski yüksek olan grupta da CT-1’in şant miktarıyla korele olarak arttığı saptandı. Sonuç olarak CT-1, erişkinlerde olduğu gibi çocuklardaki kalp yetmezliğinin değerlendirilmesinde de kullanılmaya aday bir belirteçtir. Ancak, çocukluk çağında CT-1 ile kalp fonksiyonları arasındaki ilişkiyi ortaya koymak için daha fazla sayıda hastanın incelendiği prospektif çalışmalara ihtiyaç vardır.
 
Objective: In our study, it was aimed to investigate the interaction of serum cardiotrophin-1 (CT-1) levels in left to right shunting congenital heart disease in children and to evaluate the change of this biomarker with intracardiac defect features.Material and Method: We investigated 45 patients and 23 healthy children between 1 months and 13 years of age in our study. In the patient group, we identified an atrial septal defect (ASD) in 19 cases, a ventricular septal defect (VSD) in 17 cases, an ASD and VSD (ASD+VSD) in 6 cases and a patent ductus arteriosus (PDA) in 3 cases. All children underwent a classical echocardiography (twodimensional, M-Mode, two-dimensional Doppler and colour Doppler echocardiography). In all patients, plasma BNP levels were measured by chemiluminescence and CT-1 levels were estimated by enzyme-linked immunosorbent assay (ELISA) method, synchronously with echocardiographic studies. Results: A positive correlation was detected between CT-1 and the number of shunts (p<0.02, r=0.35) in patient group and between CT-1 and the defect diameter (p<0.05, r=0.49) in ASD group. Furthermore, the level of CT-1 was higher in cases with a wide VSD than in control group (p<0,05). There was a negative correlation between CT-1 and EF and SF in the group with a higher number of shunts (pulmonary blood flow / systemic blood flow: Qp / Qs> 2) (p<0.001, r=0.71). Conclusion: CT-1 has been found to increase in the group with left to right shunting heart disease. Furthermore, it was indicated that the increase in CT-1 was related to the number of shunts in the group having more intracardiac shunts and a higher risk of failure.
 

Source

Dokuz Eylül Üniversitesi Tıp Fakültesi Dergisi

Volume

32

Issue

2

URI

https://doi.org/10.5505/deutfd.2018.25338.30074
https://app.trdizin.gov.tr/publication/paper/detail/TXpJek1Ea3hNUT09
https://hdl.handle.net/20.500.12713/272

Collections

  • Dahili Tıp Bilimleri Bölümü Makale Koleksiyonu [367]
  • DergiPark İndeksli Yayınlar Koleksiyonu [260]
  • TR-Dizin İndeksli Yayınlar Koleksiyonu [574]

Related items

Showing items related by title, author, creator and subject.

  • The Results of Intraoperative Direct Electrical Stimulation of Roots and Placode During Myelomeningocele Repair 

    Canaz, Hüseyin; Tuna Erdogan, Ezgi; Alataş, İbrahim (2018)
    INTRODUCTION: The safety of transcranial high current stimulation is controversial in newborns. However, intraoperative direct stimulation techniques are safe and useful methods even for newborns to determine the functional ...
  • The Results of Untethering Procedures with Intraoperative Neuromonitoring: Occult Spinal Dysraphism and Tethered Spinal Cord Secondary to Myelomeningocele 

    Canaz, Hüseyin; Tuna Erdogan, Ezgi; Alataş, İbrahim (2018)
    Using intraoperative neuromonitoring in both primary and secondary tethered cord operations is accepted as a necessity for a safer operation and guiding surgeon in complex surgeries. METHODS: Twenty four operations which ...
  • Recurrent multifocal pleomorphic adenoma of the parotid gland, a case report 

    Soysal, Vasif; Canturk, Mustafa; Atahan, Safak; Kaya, Ozgur Cakir; Gunen, Abdullah (2018)
    Pleomorphic adenoma is the most common benign tumor of the parotid gland .The treatment is surgery.The rate of reccurence is high when the enucleation surgery is performed. İn order to minimize the reccurences, a superficial ...



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@İSÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || İstinye University || OAI-PMH ||

İstinye University, İstanbul, Turkey
If you find any errors in content, please contact:

Creative Commons License
İstinye University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@İSÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.