JavaScript is disabled for your browser. Some features of this site may not work without it.

Calculation of NaI(Tl) detector efficiency using Ra-226, Th-232, and K-40 radioisotopes: Three-phase Monte Carlo simulation study

Thumbnail

View/Open

Tam Metin / Full Text (2.508Mb)

Date

2022

Author

Tekin, Huseyin Ozan
ALMisned, Ghada
Issa, Shams A. M.
Zakaly, Hesham M. H.
Kilic, Gokhan
Ene, Antoaneta

Metadata

Show full item record

Citation

Tekin, H. O., ALMisned, G., Issa, S. A. M., Zakaly, H. M. H., Kilic, G., Ene, A. (2022). Calculation of NaI(Tl) detector efficiency using Ra-226, Th-232, and K-40 radioisotopes: Three-phase Monte Carlo simulation study. Open Chemistry, 20(1), 541-549.

Abstract

Thallium-activated sodium iodide (NaI(Tl)) detectors can be used in gamma cameras, environmental radiation assessments, including radiation emission levels from nuclear reactors, and radiation analysis equipment. This three-phase investigation aimed to model a standard NaI(Tl) detector using the Monte Carlo N-Particle eXtended (MCNPX) general-purpose Monte Carlo simulation techniques. Accordingly, a standard NaI(Tl) detector was designed along with the required properties. Next a validation study of the modelled NaI(Tl) detector has been performed based on the experimental results for absolute detector efficiency values obtained from Ra-226, Th-232, and K-40 radioisotopes. Our findings indicate that the obtained absolute detector efficiency values are quite close to used experimental values. Finally, we used the modelled detector for determination of mass attenuation coefficients of Ordinary concrete, Lead, Hematite-serpentine concrete, and Steel-scrap concrete at 186.1, 295.22, 351.93, 609.31, 1120.29, 1764.49, 238.63, 911.2, 2614, and 1460.83 keV gamma-ray energies. Additionally, according to our findings, mass attenuation coefficients obtained from the newly designed detector are compatible with the standard NIST (XCOM) data. To conclude, continuous optimisation procedures are strongly suggested for sophisticated Monte Carlo simulations in order to maintain a high degree of simulation reliability. As a result, it can be concluded that the validation of the simulation model is necessary using measured data. Finally, it can also be concluded that the validated detector models are effective instruments for obtaining basic gamma-ray shielding parameters such as mass attenuation coefficients.

Source

OPEN CHEMISTRY

Volume

20

Issue

1

URI

https://doi.org/10.1515/chem-2022-0169
https://hdl.handle.net/20.500.12713/2985

Collections

  • Bilgisayar Mühendisliği Bölümü Makale Koleksiyonu [83]
  • Scopus İndeksli Yayınlar Koleksiyonu [1920]
  • WoS İndeksli Yayınlar Koleksiyonu [2023]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@İSÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || İstinye University || OAI-PMH ||

İstinye University, İstanbul, Turkey
If you find any errors in content, please contact:

Creative Commons License
İstinye University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@İSÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.