Comparison of the radiological parameters between dynamic-referencing tactile guidance robotic system and microplasty (r) instrumentation in unicompartmental knee arthroplasty

Thumbnail

View/Open

Tam Metin / Full Text (596.1Kb)

Date

2022

Author

Cabuk, Haluk
Turan, Kaya
Muratoglu, Osman Gorkem
Ergun, Tugrul
Ozturk, Cagatay
Erturer, Ramazan Erden

Metadata

Show full item record

Abstract

Objectives: This study aims to compare the radiological outcomes of unicompartmental knee arthroplasty (UKA) performed by a navigation-based robotic system versus Microplasty (R) instrumentation. Patients and methods: Between January 2018 and January 2019, a total of 90 knees of 75 patients (65 males, 10 females; mean age: 62.0 +/- 9.4 years; range, 50 to 73 years) were included. Among these, 54 knees underwent Oxford mobile-bearing UKA with an Microplasty (R) instrumentation set and 36 knees were operated with the aid of a Restoris (R) MCK with MAKO navigation-based robotic system. Postoperative anteroposterior and lateral X-rays of all patients were evaluated according to nine different parameters. On the femoral side, femoral varus-valgus angle, flexion-extension angle, femoral condyle posterior fit; on tibial side, tibial component varus/valgus, tibial posterior slope, medial, anterior, posterior and lateral fit of tibial component assessed. Results: There was no significant difference between groups in terms of age, sex, and affected side. On the femoral side, no significant difference was observed in the component position between groups. On the tibial side, tibial component medial fit (p=0.032) and anterior fit (p=0.007) were better in navigation-based robotic system group. Conclusion: Microplasty (R) instrumentation may lead to comparable implant positioning compared to a tactile-based navigated robotic instrumentation.

Source

JOINT DISEASES AND RELATED SURGERY

URI

http://dx.doi.org/10.52312/jdrs.2022.742
https://hdl.handle.net/20.500.12713/3352

Collections

  • Cerrahi Tıp Bilimleri Bölümü Makale Koleksiyonu [306]
  • PubMed İndeksli Yayınlar Koleksiyonu [1161]
  • Scopus İndeksli Yayınlar Koleksiyonu [1920]
  • WoS İndeksli Yayınlar Koleksiyonu [2023]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@İSÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || İstinye University || OAI-PMH ||

İstinye University, İstanbul, Turkey
If you find any errors in content, please contact:

Creative Commons License
İstinye University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@İSÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.