Trace determination of nickel in water samples by slotted quartz tube-flame atomic absorption spectrometry after dispersive assisted simultaneous complexation and extraction strategy

Thumbnail

View/Open

Tam Metin / Full Text (1.110Mb)

Date

2018

Author

Ozzeybek, Gozde
Alacakoc, Bihter
Kocabas, Mehmet Yusuf
Bakirdere, Emine Gulhan
Chormey, Dotse Selali
Bakirdere, Sezgin

Metadata

Show full item record

Citation

Ozzeybek, G., Alacakoc, B., Kocabas, M. Y., Bakirdere, E. G., Chormey, D. S., & Bakirdere, S. (2018). Trace determination of nickel in water samples by slotted quartz tube-flame atomic absorption spectrometry after dispersive assisted simultaneous complexation and extraction strategy. ENVIRONMENTAL MONITORING AND ASSESSMENT, 190(9). https://doi.org/10.1007/s10661-018-6884-z

Abstract

This study presents a new method for the determination of nickel in aqueous samples by slotted quartz tube-flame atomic absorption spectrometry (SQT-FAAS) after a dispersive assisted simultaneous complexation and extraction (DASCE) process. Synthesized ligand was directly dissolved in the extraction solvent to eliminate the complex formation step prior to the extraction. All parameters of the SQT-FAAS and DASCE method were systematically optimized to improve the detection power of nickel for trace determinations. Under the optimum experimental conditions, the optimized method (DASCE-SQT-FAAS) recorded 137-fold enhancement in detection power over the conventional FAAS. The limits of detection and quantification were determined to be 1.6 mu g/L and 5.2 mu g/L, respectively. The calibration plot was linear over a wide concentration range and the precision for replicate measurements was appreciably high. Nickel was not detected in five different water samples but spiked recovery tests for three samples yielded results that were close to 100%, confirming the method's accuracy and applicability to the matrices tested.

Source

Environmental Monitoring and Assessment

Volume

190

Issue

9

URI

https://doi.org/10.1007/s10661-018-6884-z
https://hdl.handle.net/20.500.12713/748

Collections

  • Makale Koleksiyonu [77]
  • PubMed İndeksli Yayınlar Koleksiyonu [563]
  • Scopus İndeksli Yayınlar Koleksiyonu [709]
  • WoS İndeksli Yayınlar Koleksiyonu [774]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@İSÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || İstinye University || OAI-PMH ||

İstinye University, İstanbul, Turkey
If you find any errors in content, please contact:

Creative Commons License
İstinye University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@İSÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.