Yazar "Olcay, Emin Orkun" seçeneğine göre listele
Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Effect of printing orientation on the fracture strength of additively manufactured 3-unit interim fixed dental prostheses after aging(Elsevier Science, 2022) Diken Türksayar, Almira Ada; Dönmez, Mustafa Borga; Olcay, Emin Orkun; Demirel, Münir; Demir, EsraObjectives: To evaluate the effect of printing orientation on the fracture strength of 3-unit interim fixed dental prostheses fabricated by using additive manufacturing and to compare with those fabricated by subtractive manufacturing after thermomechanical aging. Materials and Methods: A 3-unit fixed dental prosthesis was designed by using a dental design software (exocad DentalCAD 2.2 Valetta) in standard tessellation language (STL) format. This STL file was exported into a nesting software (PreForm) and 3-unit interim fixed dental prostheses with 5 different orientations (0°, 30°, 45°, 90°, and 150°) were printed by using a 3-dimensional (3D) printing interim resin (Temporary CB) (n=10). The same STL file was also used to mill polymethymethacrylate (DuoCAD) 3-unit interim fixed dental prostheses as the control group (n=10). All specimens were cemented onto cobalt-chromium test models representing a maxillary first premolar and first molar tooth with a long-term temporary cement (DentoTemp), and subjected to thermomechanical aging (120000 cycles, 1.6 Hz, 50 N, 5-55°C). Then, all specimens were loaded until fracture by using a universal tester. The data were analyzed with nonparametric 1-way analysis of variance (Kruskal- Wallis) and Dunn’s tests (? = 0.05). 3 Results: Additively manufactured specimens printed with 90° showed the lowest fracture strength values (P?.048). However, the difference between specimens printed with 45° and 90° was nonsignificant (P>.05). Milled 3-unit interim fixed dental prostheses withstood significantly higher loads than 3-unit interim fixed dental prostheses printed with 45° and 150° (P?.012). In addition, specimens printed with 0° showed higher fracture strength than the specimens printed with 45° (P=.01). Specimens printed with 0° and 30° presented similar fracture strength values with milled (P?.057) and 150° printed (P>.05) specimens. Conclusion: Printing orientation had a significant effect on the fracture strength of 3-unit interim fixed dental prostheses. Among the additively manufactured samples, those printed with 0° showed similar fracture strength values with the subtractively manufactured samples. Clinical Significance Three-unit interim fixed dental prostheses fabricated with 0° and 30° using the 3D printing interim resin tested may be alternatives to milled PMMA in terms of fracture strengthÖğe Load-to-failure resistance and optical characteristics of nano-lithium disilicate ceramic after different aging processes(MDPI, 2022) Dönmez, Mustafa Borga; Olcay, Emin Orkun; Demirel, MünirThe aim of this study was to compare the load-to-failure resistance and optical properties of nano-lithium disilicate (NLD) with lithium disilicate (LDS) and zirconia-reinforced lithium silicate (ZLS) in different aging processes. Thirty crowns were milled from NLD, LDS, and ZLS (n = 10). All crowns were subjected to thermomechanical aging and loaded until catastrophic failure. Ten specimens from each material were prepared in two different thicknesses (0.7 mm and 1.5 mm, n = 5), and color coordinates were measured before and after coffee thermocycling. Color differences (Delta E00) and relative translucency parameter (RTP) were calculated. Data were analyzed by using ANOVA and Bonferroni-corrected t-tests (alpha = 0.05). ZLS had the highest load-to-failure resistance (p <= 0.002), while the difference between LDS and NLD was nonsignificant (p = 0.776). The interaction between material type and thickness affected Delta E00 (p < 0.001). Among the 0.7 mm thick specimens, ZLS had the lowest Delta E00 (p < 0.001). Furthermore, 1.5 mm thick ZLS had lower Delta E00 than that of 1.5 mm thick LDS (p = 0.036). Other than ZLS (p = 0.078), 0.7 mm thick specimens had higher Delta E00 (p < 0.001). The interaction between material type, thickness, and thermocycling affected RTP (p < 0.001). Thinner specimens presented higher RTP (p < 0.001). NLD and LDS had higher RTP than ZLS (p <= 0.036). However, 0.7 mm thick specimens had similar RTP after coffee thermocycling (p >= 0.265). Coffee thermocycling reduced the RTP values of 0.7 mm thick NLD (p = 0.032) and LDS (p = 0.008). NLD may endure the occlusal forces present in the posterior region. However, long-term coffee consumption may impair the esthetics of restorations particularly when thin NLD is used.