Ultrasonografi rehberliğinde interskalen brakial pleksus blok uygulamasının solunum fonksiyonları ve arteriyel kan gazı üzerine etkisi

dc.authoridMuzaffer Gencer / 0000-0002-3324-5106en_US
dc.authorscopusidMuzaffer Gencer / 57218915766
dc.authorwosidMuzaffer Gencer / EWA-8922-2022
dc.contributor.authorGencer, Muzaffer
dc.date.accessioned2021-06-23T13:37:10Z
dc.date.available2021-06-23T13:37:10Z
dc.date.issued2020en_US
dc.departmentİstinye Üniversitesi, Sağlık Hizmetleri Meslek Yüksekokulu, Tıbbi Laboratuvar Teknikleri Bölümüen_US
dc.description.abstractAmaç: Çalışmamızda ultrason rehberliğinde interskalen brakial pleksus blok uygulamasının solunum fonksiyonları ve arteriyel kan gazı analizi üzerine etkisini araştırmayı amaçladık. Gereç ve Yöntem: Çalışma, omuz bölgesi ve üst kol cerrahisi planlanan, ASA I-II, cerrahi süresi 2 saati geçmeyen, pulmoner disfonksiyonu olmayan, toplam 64 hasta ile yapıldı. Cerrahi sırasında anestezi sağlamak amaçlı USG-rehberliğinde interskalen brakial pleksus blok işlemi öncesi baseline (T0) ve blok sonrası 20. dk’ da (T20) kalp hızı, non-invaziv sistolik, diyastolik ve ortalama arter basıncı ölçülerek kaydedildi. Spirometri ve arteriyel kan gazı analizi yapılarak interskalen brakial pleksus blok uygulamasının solunum fonksiyonlarına ve arteriyel kan gazı üzerine etkisi değerlendirildi. Ayrıca blok uygulaması ile ilgili veriler kaydedildi. Bulgular: Blok sonrası 20.dk’ da kalp hızında daha belirgin olmak üzere (p =0,003), sistolik (p =0,375), diyastolik (p =0,608) ve ortalama arteriyel basınçta (p =0,496) baseline (T0) değerlere göre düşme gözlendi. Blok işlemi sonrası 20.dk’ da yapılan ikinci (T20) spirometrik ölçümde, baseline (T0) ile karşılaştırıldığında, vital kapasite (VC) (4,86-3,68, p <0,001), zorlu vital kapasite (FVC), zorlu ekspiratuar volüm 1.sn (FEV1) (4,24-3,40, p <0,018), Sniff PmaxPeak (6,18-5,06) (p <0,001) ve ort. PaO2 (86,40-79,24, p <0,024)’ de önemli oranda azalma gözlendi. Bununla birlikte ortalama PaCO2 (38,62-42,34) (p <0,001) artış anlamlı düzeyde değildi. Blok sonrası, 12 hastada Horner sendrom bulguları, 6 hastada hipotansiyon-bradikardi gözlendi. Dört hastada ise ses kısıklığı gelişti. Sonuç: İnterskalen brakial pleksus bloğu tek taraflı hemidiyafragmatik pareziye neden olarak solunum fonksiyonlarını ve arteriyel oksijen basıncını etkiler ve bu sebeple pulmoner hastalığı veya kardiyak patolojisi olan hastalar için risklidir.en_US
dc.description.abstractObjective: In this study, we aimed to investigate the effect of ultrasonograpy (USG) guided interscalene brachial plexus block on pulmonary functions and arterial blood gas analysis. Material and Method: The study was carried out with 64 patients who were planned to undergo shoulder and upper arm surgery and had no pulmonary dysfunction with ASA I-II and surgery time not exceeding 2 hours. USG-guided interscalene brachial plexus block procedure (baseline, T0) and 20 minutes after block (T20) was performed to provide anesthesia during surgery. Heart rate, systolic, diastolic and mean arterial pressure was recorded after block procedure. Spirometry and arterial blood gas analysis were performed to evaluate the effect of interschalen block on pulmonary functions and arterial blood gas. In addition, data related to block application were recorded. Results: A decrease in heart rate (p =0.003), systolic (p =0.375), diastolic (p =0.608) and mean arterial pressure (p =0.496) was observed at the 20th min (T20) after the block. In the second (T20) spirometric measurement performed at the 20th minute after block, compared to baseline (T0), vital capacity (VC) (4.86- 3.68, p <0.001), forced vital capacity (FVC), forced expiratory volume 1.sec (FEV1) (4.24-3.40, p <0.018), Sniff PmaxPeak (6.18-5.06, p <0.001) and significant decrease in PaO2 (86.40-79.24, p <0,024) was observed. However, the average PaCO2 (38.62-42.34, p <0.001) increase was not significant. After the block, Horner syndrome findings were observed in 12 patients, and hypotension-bradycardia was observed in 6 patients. Hoarseness developed in 4 patients. Conclusion: Interscalene brachial plexus affects respiratory function and arterial oxygen pressure by causing unilateral hemidiaphragmatic paresis and is therefore risky for patients with pulmonary disease or cardiac pathologyen_US
dc.identifier.citationGENCER M (2020). Ultrasonografi Rehberliğinde İnterskalen Brakial Pleksus Blok Uygulamasının Solunum Fonksiyonları ve Arteriyel Kan Gazı Üzerine Etkisi . Fırat Tıp Dergisi, 25(4), 224 - 229.en_US
dc.identifier.endpage229en_US
dc.identifier.issn1300-9818en_US
dc.identifier.issn2147-124Xen_US
dc.identifier.issue4en_US
dc.identifier.startpage224en_US
dc.identifier.trdizinid423336en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12713/1827
dc.identifier.volume25en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.institutionauthorGencer, Muzaffer
dc.language.isotren_US
dc.relation.ispartofFırat Tıp Dergisien_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectArteriyel Kan Gazıen_US
dc.subjectİnterskalen Brakial Pleksus Bloğuen_US
dc.subjectSolunum Testlerien_US
dc.subjectArterial Blood Gaseen_US
dc.subjectBreathing Patternsen_US
dc.subjectInterscalene Brachial Plexus Blocken_US
dc.titleUltrasonografi rehberliğinde interskalen brakial pleksus blok uygulamasının solunum fonksiyonları ve arteriyel kan gazı üzerine etkisien_US
dc.title.alternativeThe effect of ultrasonograpy guided interscalene brachial plexus block on pulmonary functions and arterial blood gasen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
27.pdf
Boyut:
531.65 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: