Diagnostic and therapeutic radioisotopes in nuclear medicine: Determination of gamma-ray transmission factors and safety competencies of high-dense and transparent glassy shields
dc.authorid | Hüseyin Ozan Tekin / 0000-0002-0997-3488 | en_US |
dc.authorscopusid | Hüseyin Ozan Tekin / 56971130700 | |
dc.authorwosid | Hüseyin Ozan Tekin / J-9611-2016 | en_US |
dc.contributor.author | Erdemir, Rabiye Uslu | |
dc.contributor.author | Kılıç, Gökhan | |
dc.contributor.author | Baykal, Duygu Şen | |
dc.contributor.author | Almisned, Ghada | |
dc.contributor.author | Issa, Shams A. M. | |
dc.contributor.author | Zakaly, Hesham M. H. | |
dc.contributor.author | Ene, Antoaneta | |
dc.contributor.author | Tekin, Hüseyin Ozan | |
dc.date.accessioned | 2022-07-07T13:31:33Z | |
dc.date.available | 2022-07-07T13:31:33Z | |
dc.date.issued | 2022 | en_US |
dc.department | İstinye Üniversitesi, Mühendislik ve Doğa Bilimleri Fakültesi, Bilgisayar Mühendisliği Bölümü | en_US |
dc.description.abstract | We present the findings of an extensive examination on newly designed CdO-rich and transparent glass shields for nuclear medicine facilities in lieu of traditional and unfavorable materials, such as lead and concrete. Gamma-ray transmission factors of newly designed glass shields are determined using a variety of diagnostic, therapeutic, and research radioisotopes, including Ga-67, Co-57, In-111, Tl-201, Tc-99m, Cr-51, I-131, Co-58, Cs-137, Ba-133, and Co-60. A general-purpose Monte Carlo code MCNPX (version 2.7.0) is used to determine the attenuation parameters of different material thicknesses. Next, the findings are compared using a standard concrete shielding material. The results indicate that adding more CdO to the glass composition improves the overall gamma-ray attenuation properties. As a result, among the heavy and transparent glasses developed, the C40 sample containing 40% CdO exhibited the best gamma-ray absorption properties against all radioisotopes. Furthermore, the gamma-ray absorption characteristics of this created high-density glass were shown to be better to those of a standard and heavy concrete sample. It can be concluded that the newly developed CdO-rich and transparent glass sample may be used in medical radiation fields where the radioisotopes examined are used in daily clinical and research applications. | en_US |
dc.identifier.citation | Erdemir, R. U., Kilic, G., Baykal, D. S., ALMisned, G., Issa, S. A., Zakaly, H. M., ... & Tekin, H. O. (2022). Diagnostic and therapeutic radioisotopes in nuclear medicine: Determination of gamma-ray transmission factors and safety competencies of high-dense and transparent glassy shields. Open Chemistry, 20(1), 517-524. | en_US |
dc.identifier.doi | 10.1515/chem-2022-0167 | en_US |
dc.identifier.endpage | 524 | en_US |
dc.identifier.issn | 2391-5420 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.scopus | 2-s2.0-85133458737 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 517 | en_US |
dc.identifier.uri | https://10.1515/chem-2022-0167 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12713/2998 | |
dc.identifier.volume | 20 | en_US |
dc.identifier.wos | WOS:000813846500002 | en_US |
dc.identifier.wosquality | Q3 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.institutionauthor | Tekin, Hüseyin Ozan | |
dc.language.iso | en | en_US |
dc.publisher | DE GRUYTER POLAND SP Z O O | en_US |
dc.relation.ispartof | OPEN CHEMISTRY | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Nuclear Medicine | en_US |
dc.subject | Radioisotopes | en_US |
dc.subject | Gamma-Ray | en_US |
dc.subject | MCNPX | en_US |
dc.subject | Nuclear Safety | en_US |
dc.title | Diagnostic and therapeutic radioisotopes in nuclear medicine: Determination of gamma-ray transmission factors and safety competencies of high-dense and transparent glassy shields | en_US |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Küçük Resim Yok
- İsim:
- Erdemir-2022-Diagnostic-and-therapeutic-radioiso.pdf
- Boyut:
- 2.3 MB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text
Lisans paketi
1 - 1 / 1
Küçük Resim Yok
- İsim:
- license.txt
- Boyut:
- 1.44 KB
- Biçim:
- Item-specific license agreed upon to submission
- Açıklama: