May the z-tracking technique to prevent any leakage in insulin injection be an alternative to the 10-second waiting technique?
dc.authorid | İnsaf Altun / 0000-0003-1808-6263 | |
dc.authorscopusid | İnsaf Altun / 57225321209 | |
dc.authorwosid | İnsaf Altun / AAE-1839-2019 | |
dc.contributor.author | Altun, İnsaf | |
dc.date.accessioned | 2020-08-30T20:01:39Z | |
dc.date.available | 2020-08-30T20:01:39Z | |
dc.date.issued | 2018 | |
dc.department | İstinye Üniversitesi, Sağlık Bilimleri Fakültesi, Hemşirelik Bölümü | en_US |
dc.description.abstract | Correct technique in insulin delivery is an important aspect of a successful insulin therapy. Observed anomalies at injection sites are insulin leakage, pain, bleeding, inflammation, bruising, lipoatrophy, and lipohypertrophy. Possible concerns regarding incorrect insulin application technique include greater insulin leakage and back flow. Reflux from the injection site is by far the most frequently reported type of leaking patients report. Incidence is variable and etiology is unclear. Leakage influences patients’ perception of insulin administration because patients are concerned whether they have received the correct dosage. | en_US |
dc.identifier.citation | Altun, İ. (2018). May the Z-Tracking Technique to Prevent Any Leakage in Insulin Injection Be an Alternative to the 10-Second Waiting Technique?. Journal of diabetes science and technology, 12(2), 537-538. | en_US |
dc.identifier.doi | 10.1177/1932296817730378 | en_US |
dc.identifier.endpage | 538 | en_US |
dc.identifier.issn | 1932-2968 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.pmid | 28918650 | en_US |
dc.identifier.scopus | 2-s2.0-85042109478 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.startpage | 537 | en_US |
dc.identifier.uri | https://doi.org/10.1177/1932296817730378 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12713/337 | |
dc.identifier.volume | 12 | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.institutionauthor | Altun, İnsaf | en_US |
dc.language.iso | en | en_US |
dc.publisher | SAGE Publications Inc. | en_US |
dc.relation.ispartof | Journal of Diabetes Science and Technology | en_US |
dc.relation.publicationcategory | Diğer | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | 10-Second Waiting Technique | en_US |
dc.subject | Insulin Injection | en_US |
dc.subject | Prevents Any Leakage | en_US |
dc.subject | Z-Tracking Technique | en_US |
dc.title | May the z-tracking technique to prevent any leakage in insulin injection be an alternative to the 10-second waiting technique? | en_US |
dc.type | Letter | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- 44s.pdf
- Boyut:
- 50.58 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin / Full Text