Investigation of Radiochromic Film Use for Source Position Verification through a LINAC On-Board Imager (OBI)

dc.authoridALMISNED, GHADA/0000-0001-9072-4480
dc.authoridEne, Antoaneta/0000-0002-6976-0767
dc.authoridTekin, Huseyin Ozan/0000-0002-0997-3488
dc.authoridKaracam, Songul/0000-0002-0904-489X
dc.authorwosidALMISNED, GHADA/AIF-4569-2022
dc.authorwosidTunçman, Duygu/JNR-9551-2023
dc.authorwosidEne, Antoaneta/C-1386-2011
dc.authorwosidTekin, Huseyin Ozan/J-9611-2016
dc.contributor.authorKaracam, Songul Cavdar
dc.contributor.authorTuncman, Duygu
dc.contributor.authorALMisned, Ghada
dc.contributor.authorEne, Antoaneta
dc.contributor.authorTekin, Huseyin Ozan
dc.date.accessioned2024-05-19T14:41:34Z
dc.date.available2024-05-19T14:41:34Z
dc.date.issued2023
dc.departmentİstinye Üniversitesien_US
dc.description.abstractBackground and Objectives: Quality assurance is an integral part of brachytherapy. Traditionally, radiographic films have been used for source position verification, however, in many clinics, computerized tomography simulators have replaced conventional simulators, and computerized radiography systems have replaced radiographic film processing units. With these advances, the problem of controlling source position verification without traditional radiographic films and conventional simulators has appeared. Materials and Methods: In this study, we investigated an alternative method for source position verification for brachytherapy applications. Source positions were evaluated using Gafchromic (TM) RTQA2 and EBT3 film and visually compared to exposed RTQA radiochromic film when using a Nucletron Oldelft Simulix HP conventional simulator and a Gammamed 12-i brachytherapy device for performance evaluation. Gafchromic film autoradiography was performed with a linear accelerator (LINAC) on-board imager (OBI). Radiochromic films are very suitable for evaluation by visual inspection with a LINAC OBI. Results: The results showed that this type of low-cost, easy-to-find material can be used for verification purposes under clinical conditions. Conclusions: It can be concluded that source-position quality assurance may be performed through a LINAC OBI device.en_US
dc.description.sponsorshipPrincess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia [PNURSP2023R149]en_US
dc.description.sponsorshipPrincess Nourah bint Abdulrahman University Researchers Supporting Project number (PNURSP2023R149), Princess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia.en_US
dc.identifier.doi10.3390/medicina59030628
dc.identifier.issn1010-660X
dc.identifier.issn1648-9144
dc.identifier.issue3en_US
dc.identifier.pmid36984628en_US
dc.identifier.scopus2-s2.0-85151740241en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.urihttps://doi.org10.3390/medicina59030628
dc.identifier.urihttps://hdl.handle.net/20.500.12713/5127
dc.identifier.volume59en_US
dc.identifier.wosWOS:000960047000001en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherMdpien_US
dc.relation.ispartofMedicina-Lithuaniaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.snmz20240519_kaen_US
dc.subjectFilm Dosimetryen_US
dc.subjectBrachytherapyen_US
dc.subjectQuality Assuranceen_US
dc.subjectLinac On-Board Imageren_US
dc.titleInvestigation of Radiochromic Film Use for Source Position Verification through a LINAC On-Board Imager (OBI)en_US
dc.typeArticleen_US