Measurement of LYSO crystal light output and energy resolution improvement with acid etching
dc.authorid | Kolcu, Onur Bugra/0000-0002-9177-1286 | |
dc.contributor.author | Kolcu, O. B. | |
dc.contributor.author | Iren, E. | |
dc.contributor.author | Yetkin, T. | |
dc.contributor.author | Ozok, F. | |
dc.contributor.author | Erduran, M. N. | |
dc.date.accessioned | 2024-05-19T14:39:59Z | |
dc.date.available | 2024-05-19T14:39:59Z | |
dc.date.issued | 2023 | |
dc.department | İstinye Üniversitesi | en_US |
dc.description.abstract | In this study, we investigated the impact of chemical etching on the light output and energy resolution of LYSO scintillators using simple, affordable laboratory equipment. We found that etching with phosphoric acid at temperatures between 180 degrees C and 190 degrees C improved the light output and energy resolution compared to mechanically polished crystals, even after minimal etching times. Our results show that with 7.5 min of chemical etching, the light output increase rate is 45.7%, and the relative energy resolution improvement is 12%. | en_US |
dc.description.sponsorship | Scientific and Technological Research Council of Turkey (TUuml;BITAK) [119F133] | en_US |
dc.description.sponsorship | We would like to thank Bilal Cakir, Istanbul Sabahattin Zaim and Istinye University chemistry laboratory staff for their support in pro- viding equipment. This work was supported by the Scientific and Technological Research Council of Turkey (TUBITAK) under grant number 119F133. | en_US |
dc.identifier.doi | 10.1016/j.apradiso.2023.110902 | |
dc.identifier.issn | 0969-8043 | |
dc.identifier.issn | 1872-9800 | |
dc.identifier.pmid | 37379787 | en_US |
dc.identifier.scopus | 2-s2.0-85163871401 | en_US |
dc.identifier.scopusquality | Q3 | en_US |
dc.identifier.uri | https://doi.org10.1016/j.apradiso.2023.110902 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12713/4885 | |
dc.identifier.volume | 199 | en_US |
dc.identifier.wos | WOS:001034099900001 | en_US |
dc.identifier.wosquality | N/A | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Pergamon-Elsevier Science Ltd | en_US |
dc.relation.ispartof | Applied Radiation and Isotopes | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.snmz | 20240519_ka | en_US |
dc.subject | Chemical Etching | en_US |
dc.subject | Scintillator Light Output | en_US |
dc.subject | Scintillator Polishing | en_US |
dc.subject | Surface Treatment | en_US |