Computed tomography-guided optimization of needle insertion for combined intracavitary/interstitial brachytherapy with utrecht applicator in locally advanced cervical cancer

dc.authoridMerdan Fayda / 0000-0002-2800-5327en_US
dc.authorscopusidMerdan Fayda / 6506348846
dc.authorwosidMerdan Fayda / AAF-7370-2019
dc.contributor.authorTambas, Makbule
dc.contributor.authorTavlı, Büşra
dc.contributor.authorBilici, Nazlı
dc.contributor.authorDizman, Aysen
dc.contributor.authorSertel, Hüseyin
dc.contributor.authorFayda, Merdan
dc.date.accessioned2021-02-09T09:30:43Z
dc.date.available2021-02-09T09:30:43Z
dc.date.issued2021en_US
dc.departmentİstinye Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümüen_US
dc.description.abstractPurpose: There are no international guidelines for optimal needle insertion during interstitial intracavitary brachytherapy (IS-ICBT) for cervical cancer. We aimed to investigate the clinical feasibility and added value of computed tomography (CT) guidance to optimize needle insertion in IS-ICBT using the Utrecht applicator and to evaluate needle shifts. Methods and Materials: We enrolled 24 patients who were treated with IS-BT. Two CT scans each were performed for every patient: 1) after applicator insertion without needles (CTpreneedle); 2) after needle insertion (CTpostneedle). In addition to magnetic resonance imaging (MRI) after external-beam radiotherapy, CTpreneedle was used to determine optimal needle locations and insertion lengths based on applicator and organs at risk positioning on the day of treatment; CTpostneedle was used for IS-ICBT planning. The needle-channel axis was used as a reference to determine needle-shift evolution. Results: A total of 266 interstitial needles were inserted in 76 of 93 BT fractions with high intra- and interpatient variations in the number of inserted needles. Based on CTpreneedle findings, needle insertion was avoided in nine, four, two, and two patients at the first, second, third, and fourth fractions, respectively. The unloaded needle frequency was 4%. Average needle contribution to total dwell time was 37.2±19.2%. Shifting was observed in 68% of the needles (mean shift 2.0±2.3 mm), mostly in the posterior direction, and in needles with a larger insertion length. Needle reinsertion was not needed in any patient. No complication due to needle insertion was observed, except for minor vaginal bleeding in one patient after needle removal.en_US
dc.identifier.citationTambas, M., Tavli, B., Bilici, N., Dizman, A., Sertel, H., & Fayda, M. (2021). Computed Tomography-guided Optimization of Needle Insertion For Combined Intracavitary/Interstitial Brachytherapy With Utrecht Applicator in Locally Advanced Cervical Cancer. Practical radiation oncology, S1879-8500(21)00043-6. Advance online publication. https://doi.org/10.1016/j.prro.2021.01.008en_US
dc.identifier.doi10.1016/j.prro.2021.01.008en_US
dc.identifier.issn1879-8500en_US
dc.identifier.pmid33556579en_US
dc.identifier.scopus2-s2.0-85103095886en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.urihttps://doi.org/10.1016/j.prro.2021.01.008
dc.identifier.urihttps://hdl.handle.net/20.500.12713/1435
dc.identifier.wosWOS:000674490600009en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorFayda, Merdan
dc.language.isoenen_US
dc.publisherElsevier Inc.en_US
dc.relation.ispartofPractical Radiation Oncologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleComputed tomography-guided optimization of needle insertion for combined intracavitary/interstitial brachytherapy with utrecht applicator in locally advanced cervical canceren_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
15.pdf
Boyut:
833.8 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: