Effect of substrate adjacent to the scan region on the trueness of four intraoral scanners: An in vitro study

dc.authoridElter, Bahar/0000-0002-8971-6819
dc.contributor.authorElter, Bahar
dc.contributor.authorTak, Onjen
dc.date.accessioned2024-05-19T14:40:46Z
dc.date.available2024-05-19T14:40:46Z
dc.date.issued2023
dc.departmentİstinye Üniversitesien_US
dc.description.abstractObjectives: The purpose of this in vitro study was to evaluate the trueness of four commercially available intraoral scanners (IOSs) on scanning different substrates that existed in the adjacent proximal contact area.Methods: Four IOSs (TRIOS 4, TRIOS 3, Primescan, Omnicam) were used for scanning the intact enamel surface of a molar tooth, and six restorative materials (zirconia, lithium disilicate glass-ceramic, composite resin, hybrid ceramic, feldspathic ceramic, metal) that were located at the adjacent proximal contact area of the same tooth. Reference scans were obtained using an extraoral scanner (inEos X5). A 3-dimensional analyzing software (Geomagic Control X) was used to compare the reference and tested scans. The two-way analysis of variance (ANOVA) followed by Bonferroni correction was performed for statistical analyses (alpha=0.05).Results: TRIOS 3 and TRIOS 4 showed higher trueness than Primescan, and Primescan showed higher trueness than Omnicam (p<0.001), while there were no differences between TRIOS 3 and TRIOS 4. Metal showed significantly higher Root Mean Square values (0.273 +/- 0.24 mm) than other substrates. No difference was found between the scanners' zirconia, lithium disilicate glass-ceramic, composite, and feldspathic ceramic scans (p > 0.05). For the metal, TRIOS 3 and TRIOS 4 showed higher trueness than Primescan and Omnicam, while Omnicam showed lower trueness among all scanners. For the hybrid ceramic, TRIOS 3 showed higher trueness than Omnicam (p<0.001). For the enamel, TRIOS 3 showed higher trueness than Primescan and Omnicam (p<0.001).Conclusions: The trueness of IOSs can be affected by the substrates that exist in the proximal contact area. Amongst all, the metal substrate affected most the trueness of the IOSs.Clinical Significance: The clinician should decide on the impression system, taking into account that the IOS and the surfaces to be scanned affect the trueness of the digital data. The deviation of the digital impression would be high in the presence of a metal restoration on the adjacent proximal surface.en_US
dc.identifier.doi10.1016/j.jdent.2023.104729
dc.identifier.issn0300-5712
dc.identifier.issn1879-176X
dc.identifier.pmid37778497en_US
dc.identifier.scopus2-s2.0-85173219668en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.urihttps://doi.org10.1016/j.jdent.2023.104729
dc.identifier.urihttps://hdl.handle.net/20.500.12713/5012
dc.identifier.volume138en_US
dc.identifier.wosWOS:001103036200001en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherElsevier Sci Ltden_US
dc.relation.ispartofJournal of Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.snmz20240519_kaen_US
dc.subjectDental Materialsen_US
dc.subjectDigital Impressionen_US
dc.subjectIntraoral Scanneren_US
dc.subjectProximal Contact Areaen_US
dc.subjectTruenessen_US
dc.titleEffect of substrate adjacent to the scan region on the trueness of four intraoral scanners: An in vitro studyen_US
dc.typeArticleen_US

Dosyalar