Establishment of diagnostic reference levels in cone beam computed tomography scans in the united arab emirates

dc.authoridHüseyin Ozan Tekin / 0000-0002-0997-3488en_US
dc.authorscopusidHüseyin Ozan Tekin / 56971130700en_US
dc.authorwosidHüseyin Ozan Tekin / J-9611-2016en_US
dc.contributor.authorAbuzaid, Mohamed M.
dc.contributor.authorElshami, Wiam
dc.contributor.authorJayachandran, Deepa
dc.contributor.authorKorappil, Noushad
dc.contributor.authorTekin, Hüseyin Ozan
dc.date.accessioned2022-12-30T09:16:55Z
dc.date.available2022-12-30T09:16:55Z
dc.date.issued2022en_US
dc.departmentİstinye Üniversitesi, Mühendislik ve Doğa Bilimleri Fakültesi, Bilgisayar Mühendisliği Bölümüen_US
dc.description.abstractThis study aimed to address the knowledge gap in assessing the radiation doses from cone beam computed tomography (CBCT) procedures, establishing a typical value, and estimating effective and organ doses. A total of 340 patients aged 18-80 years were included in this study. Organ doses were estimated using VirtualDose IR software. The typical values were based on median values estimated as 1000 mGy cm2. The mean ED (µSv) per procedure was 149.5 ± 56, and the mean of the peak skin dose during the CBCT examination was 39.29 mGy. The highest organ dose was received by the salivary glands (2.71 mGy), the extrathoracic region (1.64 mGy), thyroid (1.24 mGy) and eyes (0.61 mGy). The patients' doses were higher than in previous studies. Staff awareness, education, training and dose optimisation are highly recommended. With the establishment of local DRLs, patient dosages can be reduced successfully without compromising image quality.en_US
dc.identifier.citationAbuzaid, M. M., Elshami, W., Jayachandran, D., Korappil, N., & Tekin, H. O. (2022). Establishment of Diagnostic Reference Levels in Cone Beam Computed Tomography Scans in the United Arab Emirates. Tomography (Ann Arbor, Mich.), 8(6), 2939–2945. https://doi.org/10.3390/tomography8060247en_US
dc.identifier.doi10.3390/tomography8060247.en_US
dc.identifier.endpage2945en_US
dc.identifier.issue6en_US
dc.identifier.pmid36548539en_US
dc.identifier.startpage2939en_US
dc.identifier.urihttp://dx.doi.org/10.3390/tomography8060247.
dc.identifier.urihttps://hdl.handle.net/20.500.12713/3795
dc.identifier.volume8en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorTekin, Hüseyin Ozan
dc.language.isoenen_US
dc.publisherMDPIen_US
dc.relation.ispartofTomographyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subject(CBCT) Cone-Beam Computed Tomographyen_US
dc.subject(DRL) Diagnostic Reference Levelen_US
dc.subjectEffective Dose; Organ Doseen_US
dc.titleEstablishment of diagnostic reference levels in cone beam computed tomography scans in the united arab emiratesen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Abuzaid-2022-Establishment-of-diagnostic-referen.pdf
Boyut:
697.45 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: