Effect of scanned area and operator on the accuracy of dentate arch scans with a single implant

dc.authoridMustafa Borga Dönmez / 0000-0002-3094-7487en_US
dc.authorscopusidMustafa Borga Dönmez / 57202022054
dc.authorwosidMustafa Borga Dönmez / AGY-6155-2022en_US
dc.contributor.authorMarques, Vinicius Rizzo
dc.contributor.authorÇakmak, Gülce
dc.contributor.authorYılmaz, Hakan
dc.contributor.authorAbou-Ayash, Samir
dc.contributor.authorDönmez, Mustafa Borga
dc.contributor.authorYılmaz, Burak
dc.date.accessioned2022-07-30T11:09:58Z
dc.date.available2022-07-30T11:09:58Z
dc.date.issued2022en_US
dc.departmentİstinye Üniversitesi, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.description.abstractStudies have shown the effect of the operator and scanned areas on the accuracy of single implant scans. However, the knowledge on the scan accuracy of the remaining dental arch during single implant scans, which may affect the occlusion, is limited. The aim of this study was to investigate the effect of scanned areas and the operator on the scan accuracy of a dentate arch while scanning a single implant. A dentate model with an anterior implant was digitized with a laboratory scanner (reference scan). Three operators with similar experience performed 10 complete- and 10 partial-arch scans (left 2nd molar to right canine) with an intraoral scanner (TRIOS 3), and these scans were superimposed over the reference. The accuracy was analyzed at 22 points in complete-arch and at 16 points in partial-arch scans on 2nd molars and incisors. Data were evaluated with 2-way ANOVA and Tukey HSD tests (? = 0.05). The trueness of the total scanned area was higher in partialthan in complete-arch scans (p < 0.001). The trueness and precision of the scans were higher in the anterior site compared with the posterior in complete- (trueness: p ? 0.022, precision: p ? 0.003) and partial-arch (trueness: p ? 0.016, precision: p ? 0.016) scans of each operator and when the operator scan data were pooled. The complete-arch scan’s precision was not influenced by the operator (p ? 0.029), whereas the partial-arch scans of operator 1 and 2 were significantly different (p = 0.036). Trueness was higher in partial- compared with complete-arch scans, but their precision was similar. Accuracy was higher in the anterior site regardless of the scan being a partial- or a complete-arch. The operator’s effect on the accuracy of partial- and complete-arch scans was small.en_US
dc.identifier.citationMarques VR, Çakmak G, Yilmaz H, Abou-Ayash S, Donmez MB, Yilmaz B. Effect of Scanned Area and Operator on the Accuracy of Dentate Arch Scans with a Single Implant. J Clin Med. 2022 Jul 15;11(14):4125. doi: 10.3390/jcm11144125. PMID: 35887889.en_US
dc.identifier.doi10.3390/jcm11144125en_US
dc.identifier.issn2077-0383en_US
dc.identifier.issue14en_US
dc.identifier.pmid35887889en_US
dc.identifier.scopus2-s2.0-85136367538en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.urihttp://doi.org/10.3390/jcm11144125
dc.identifier.urihttps://hdl.handle.net/20.500.12713/3058
dc.identifier.volume11en_US
dc.identifier.wosWOS:000832289900001en_US
dc.identifier.wosqualityQ2en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorDönmez, Mustafa Borga
dc.language.isoenen_US
dc.publisherMDPIen_US
dc.relation.ispartofJournal of Clinical Medicineen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectImplant Scanen_US
dc.subjectOperatoren_US
dc.subjectPrecisionen_US
dc.subjectScan Areaen_US
dc.subjectTruenessen_US
dc.titleEffect of scanned area and operator on the accuracy of dentate arch scans with a single implanten_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
jcm-11-04125-v2.pdf
Boyut:
2.71 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: