Trueness and precision of mandibular complete-arch implant scans when different data acquisition methods are used

dc.authoridDonmez, Mustafa Borga/0000-0002-3094-7487
dc.authoridDEMİREL, Münir/0000-0002-1487-6834
dc.authorwosidDonmez, Mustafa Borga/AGY-6155-2022
dc.authorwosidDEMİREL, Münir/GZK-2087-2022
dc.contributor.authorDemirel, Munir
dc.contributor.authorDonmez, Mustafa Borga
dc.contributor.authorSahmali, Sevil Meral
dc.date.accessioned2024-05-19T14:38:47Z
dc.date.available2024-05-19T14:38:47Z
dc.date.issued2023
dc.departmentİstinye Üniversitesien_US
dc.description.abstractObjectives: To evaluate the effect of different data acquisition methods on the trueness and precision of mandibular complete-arch implant scans.Methods: An edentulous polyurethane master mandibular model with 6 implants was digitized by using an industrial-grade blue light scanner (ATOS Core 80 5MP) to obtain a master standard tessellation language (MSTL) file. The master model was also digitized by using either direct digital workflow with a stereoscopic camera (iCam 4D (IM)) or intraoral scanners (CEREC Primescan (PS) and Trios 4 (T4)) or indirect digital workflow with laboratory scanners (inEos X5 (X5) and CARES 7 (S7)) to obtain test-scan STLs (n = 10). All STL files were imported into a metrology-grade analysis software (Geomagic Control X 2020.1) and test-scan STLs were superimposed over MSTL. The root mean square method was used to calculate surface deviations, while angular deviations were also calculated. Kruskal-Wallis and Dunn's tests were used to evaluate measured deviations (surface and angular) for trueness and precision (alpha = 0.05).Results: X5 and S7 had the lowest, and IM had the highest surface deviations (P <= .036). The angular deviations of PS were lower than those of X5, S7, and IM (P <= .008). When surface deviations were considered, T4 had the lowest precision among tested scanners (P <= .002), and the scans of IM had higher precision than those of PS (P = .003). Scanner type did not affect the precision of the scans when angular deviations were considered (P = .084).Conclusions: The data acquisition method affected the trueness (surface and angular deviations) and precision (surface deviations) of mandibular complete-arch implant scans. Clinical significance: Tested data acquisition methods may be feasible to digitize mandibular complete-arch implants considering the deviations of the scans, which were in the range of previously reported thresholds, and the high precision of scans. However, the frameworks fabricated with the direct digital workflow that involves the scans of the stereoscopic camera might require more adjustments than those fabricated by using the scans of other tested scanners.en_US
dc.description.sponsorshipResearch Fund of the Biruni University Biratto Directorate, Turkey [Biruni-BAP-2022-0102]en_US
dc.description.sponsorshipThis study was funded by the Research Fund of the Biruni University Biratto Directorate, Turkey with the grant number Biruni-BAP-2022-0102.en_US
dc.identifier.doi10.1016/j.jdent.2023.104700
dc.identifier.issn0300-5712
dc.identifier.issn1879-176X
dc.identifier.pmid37714451en_US
dc.identifier.scopus2-s2.0-85171856511en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.urihttps://doi.org10.1016/j.jdent.2023.104700
dc.identifier.urihttps://hdl.handle.net/20.500.12713/4607
dc.identifier.volume138en_US
dc.identifier.wosWOS:001084610300001en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherElsevier Sci Ltden_US
dc.relation.ispartofJournal of Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.snmz20240519_kaen_US
dc.subjectAccuracyen_US
dc.subjectComplete-Archen_US
dc.subjectDigital Workflowen_US
dc.subjectImplanten_US
dc.subjectStereoscopic Cameraen_US
dc.titleTrueness and precision of mandibular complete-arch implant scans when different data acquisition methods are useden_US
dc.typeArticleen_US

Dosyalar