Effect of number of supports and build angle on the fabrication and internal fit accuracy of additively manufactured definitive resin-ceramic hybrid crowns

dc.authoridDonmez, Mustafa Borga/0000-0002-3094-7487
dc.authoridCakmak, Gulce/0000-0003-1751-9207
dc.authoridSchimmel, Martin/0000-0001-9700-5534
dc.authoridPaula, Marcella/0000-0001-6078-6760
dc.authorwosidCakmak, Gulce/GRE-6472-2022
dc.authorwosidDonmez, Mustafa Borga/AGY-6155-2022
dc.authorwosidSchimmel, Martin/F-5694-2011
dc.contributor.authorCakmak, Gulce
dc.contributor.authorAgovic, Dino
dc.contributor.authorDonmez, Mustafa Borga
dc.contributor.authorKahveci, Cigdem
dc.contributor.authorde Paula, Marcella Silva
dc.contributor.authorSchimmel, Martin
dc.contributor.authorYilmaz, Burak
dc.date.accessioned2024-05-19T14:38:51Z
dc.date.available2024-05-19T14:38:51Z
dc.date.issued2023
dc.departmentİstinye Üniversitesien_US
dc.description.abstractObjectives: To evaluate the effect of number of supports and build angle on the fabrication and internal fit ac-curacy (trueness and precision) of additively manufactured resin-ceramic hybrid crowns. Methods: A mandibular first molar crown was designed and nested on the build platform of a printer either with a 30 degrees angle between the occlusal surface and the build platform (BLS (less support) and BMS (more support)) or its occlusal surface parallel to the build platform (VLS (less support) and VMS (more support)) to fabricate addi-tively manufactured resin-ceramic hybrid crowns (n = 14). After fabrication, supports were removed by a blinded operator and all crowns were digitized with an intraoral scanner. Fabrication accuracy (overall, external, intaglio occlusal, occlusal, and marginal) was evaluated by using root mean square (RMS) method, while internal fit was evaluated with triple scan method. RMS, average gap, and precision of these data were analyzed (alpha= 0.05).esults: VLS had higher overall deviations than BLS and VMS (P <=.039). VMS had higher occlusal deviations than BLS (P=.033). While BMS and BLS had higher marginal deviations than VLS (P <=.006), BMS also had higher values than VMS (P=.012). BLS led to higher precision than VMS (intaglio occlusal and occlusal surfaces) and VLS (occlusal surface) (P <=.008). VLS led to higher precision than BMS (marginal surface) (P=.027). Average gap values were similar (P=.723); however, BLS resulted in higher precision than VLS (P=.018).Conclusions: Considering their high marginal and occlusal surface trueness, and similar internal occlusal de-viations and average gaps (trueness), clinical fit of resin-ceramic hybrid crowns fabricated with tested parameters may be similar. Reduced number of supports and angled orientation may lead to higher precision of fit. Clinical Significance: Tested resin-ceramic hybrid-printer pair may be used to fabricate crowns with reduced number of supports to maintain occlusal surface integrity without compromising the fabrication accuracy and fit.en_US
dc.identifier.doi10.1016/j.jdent.2023.104548
dc.identifier.issn0300-5712
dc.identifier.issn1879-176X
dc.identifier.pmid37192693en_US
dc.identifier.scopus2-s2.0-85159260927en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.urihttps://doi.org10.1016/j.jdent.2023.104548
dc.identifier.urihttps://hdl.handle.net/20.500.12713/4628
dc.identifier.volume134en_US
dc.identifier.wosWOS:001000944500001en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherElsevier Sci Ltden_US
dc.relation.ispartofJournal of Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.snmz20240519_kaen_US
dc.subjectAdditive Manufacturingen_US
dc.subjectBuild Angleen_US
dc.subjectDefinitive Composite Resinen_US
dc.subjectFabrication Truenessen_US
dc.subjectSupporten_US
dc.titleEffect of number of supports and build angle on the fabrication and internal fit accuracy of additively manufactured definitive resin-ceramic hybrid crownsen_US
dc.typeArticleen_US

Dosyalar