Exploring the Radioprotective Indium (III) Oxide Screens for Mammography Scans Using a Three-Layer Heterogeneous Breast Phantom and MCNPX: A Comparative Study Using Clinical Findings

dc.authoridKILIC, Gokhan/0000-0002-6762-6898
dc.authoridEne, Antoaneta/0000-0002-6976-0767
dc.authoridZAKALY, Hesham M.H./0000-0002-7645-9964
dc.authoridIlik, Erkan/0000-0003-2986-0015
dc.authoridTekin, Huseyin Ozan/0000-0002-0997-3488
dc.authoridALMISNED, GHADA/0000-0001-9072-4480
dc.authoridElshami, Wiam/0000-0003-1342-7452
dc.authorwosidKILIC, Gokhan/AAH-8955-2021
dc.authorwosidEne, Antoaneta/C-1386-2011
dc.authorwosidZAKALY, Hesham M.H./E-8136-2016
dc.authorwosidIlik, Erkan/HJZ-4536-2023
dc.authorwosidTekin, Huseyin Ozan/J-9611-2016
dc.authorwosidALMISNED, GHADA/AIF-4569-2022
dc.contributor.authorALMisned, Ghada
dc.contributor.authorElshami, Wiam
dc.contributor.authorKilic, Gokhan
dc.contributor.authorIlik, Erkan
dc.contributor.authorRabaa, Elaf
dc.contributor.authorZakaly, Hesham M. H.
dc.contributor.authorEne, Antoaneta
dc.date.accessioned2024-05-19T14:39:38Z
dc.date.available2024-05-19T14:39:38Z
dc.date.issued2023
dc.departmentİstinye Üniversitesien_US
dc.description.abstractBackground: During mammography, a lead-acrylic protective screen is recommended to reduce radiation exposure to the unexposed breast. Objectives: This research study aimed to construct an Indium-(III)-oxide-rich tellurite-glass screen (TZI8) and compare its performance to that of lead acrylic. Materials and Methods: A three-layer heterogeneous-breast phantom was developed, using the MCNPX (version 2.7.0) Monte Carlo code. An MCNPX-simulation geometry was designed and implemented, using the lead-acrylic and TZI8 shielding screens between the right and left breast. Next, the reliability of the phantom and the variations in absorption between the lead-acrylic and TZI8 glass were investigated. Results: The findings show that the TZI8-protective-glass screen offers significantly greater radioprotection than the lead-acrylic material. The quantity of total dose absorbed in the unexposed breast was much lower for TZI8 than for lead-based acrylic. The TZI8-glass screen gives about 60% more radioprotection than the lead-acrylic screen. Conclusion: Considering the toxic lead in the structure that may be hazardous to the human tissues, the TZI8-glass screen may be used in mammography examination to provide greater radioprotection than the lead-acrylic screen, in order to greatly reduce the dose to the unexposed breast.en_US
dc.description.sponsorshipPrincess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia [PNURSP2023R149]en_US
dc.description.sponsorshipThe authors would like to express their deepest gratitude to Princess Nourah bint Abdulrahman University Researchers Supporting Project number (PNURSP2023R149), Princess Nourah bint Abdulrahman University, Riyadh, Saudi Arabia.en_US
dc.identifier.doi10.3390/medicina59020327
dc.identifier.issn1010-660X
dc.identifier.issn1648-9144
dc.identifier.issue2en_US
dc.identifier.pmid36837529en_US
dc.identifier.scopus2-s2.0-85148883724en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.urihttps://doi.org10.3390/medicina59020327
dc.identifier.urihttps://hdl.handle.net/20.500.12713/4821
dc.identifier.volume59en_US
dc.identifier.wosWOS:000941566600001en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherMdpien_US
dc.relation.ispartofMedicina-Lithuaniaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.snmz20240519_kaen_US
dc.subjectBreast Dosimetryen_US
dc.subjectMammographyen_US
dc.subjectX-Rayen_US
dc.subjectRadiation Protectionen_US
dc.titleExploring the Radioprotective Indium (III) Oxide Screens for Mammography Scans Using a Three-Layer Heterogeneous Breast Phantom and MCNPX: A Comparative Study Using Clinical Findingsen_US
dc.typeArticleen_US

Dosyalar