Özet
Statement of problem: Additive and subtractive manufacturing have become alternative technologies for fabricating occlusal devices. However, knowledge of the long-term stability of occlusal devices fabricated using these recent technologies is limited. Purpose: The purpose of this in vitro study was to evaluate the cameo and intaglio surface stability and variability of additively, subtractively, and conventionally manufactured occlusal devices after 18 months of storage. Material and methods: A standard tessellation language (STL) file of a dentate maxillary typodont was used to design a master occlusal device. The STL file of this design was used to fabricate occlusal devices additively either with a digital light processing (AM-1) or a continuous liquid interface production (AM-2) printer, subtractively with 2 different 5-axis milling units (SM-1 and SM-2), and conventionally (TM-HP) (n=10). STL files of each device's cameo and intaglio surfaces were generated using a laboratory scanner after fabrication and after 18 months of storage in a moist environment. These generated files were imported into an analysis software program (Geomagic Control X) to analyze the dimensional stability of tested devices by using the root mean square method. The average deviation values defined the variability of measured changes over time. Cameo and intaglio surface deviations were analyzed using the Kruskal-Wallis and Dunn tests, while the variability of measured deviations was analyzed with 1-way analysis of variance and the Tukey HSD tests (α=.05). Results: Significant differences were observed among tested devices when the intaglio surface deviations and the cameo surface variability were considered (P<.001). SM-2 had significantly higher intaglio surface deviations than AM-1, SM-1, and AM-2 (P≤.036). Among the test groups, AM-1 had the greatest cameo surface variability (P≤.004). Conclusions: SM-2 resulted in lower intaglio surface stability than the additive and the other subtractive manufacturing technologies, while AM-1 led to the highest cameo surface variability among the test groups.
Açıklama
Anahtar Kelimeler
Kaynak
Journal of prosthetic dentistry
WoS Q Değeri
Q1
Scopus Q Değeri
Q1
Cilt
132
Sayı
3
Künye
Orgev, A., Donmez, M. B., Almogbel, L., Cakmak, G., Marques, V. R., Kahveci, C., & Yilmaz, B. (2024). Cameo and intaglio surface stability and variability of additively, subtractively, and conventionally manufactured occlusal devices after long-term storage. The Journal of Prosthetic Dentistry, 132(3), 604-e1.