Trueness of crowns fabricated by using additively and subtractively manufactured resin-based CAD-CAM materials

dc.authoridMustafa Borga Dönmez / 0000-0002-3094-7487en_US
dc.authorscopusidMustafa Borga Dönmez / 57202022054en_US
dc.authorwosidMustafa Borga Dönmez / AGY-6155-2022en_US
dc.contributor.authorÇakmak, Gülce
dc.contributor.authorRusa, Ana Maria
dc.contributor.authorDönmez, Mustafa Borga
dc.contributor.authorAkay, Canan
dc.contributor.authorKahveci, Çiğdem
dc.contributor.authorYılmaz, Burak
dc.date.accessioned2022-12-30T08:51:22Z
dc.date.available2022-12-30T08:51:22Z
dc.date.issued2022en_US
dc.departmentİstinye Üniversitesi, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.description.abstractStatement of problem: Advancements in digital dental technologies have enabled the use of different resin-based materials that can be fabricated either additively or subtractively. However, knowledge on the fabrication trueness of these materials is scarce. Purpose: The purpose of this in vitro study was to investigate the trueness of crowns fabricated by using different resin-based computer-aided design and computer-aided manufacturing (CAD-CAM) materials. Material and methods: A complete crown for a mandibular right first molar with a 30-?m cement space was designed in standard tessellation language (STL) format. This master STL (MC-STL) was used to fabricate 40 complete crowns with 4 different resin-based CAD-CAM materials and either additive (Crowntec [MS]) or subtractive techniques (Brilliant Crios [BC], breCAM.monoCOM [PMMA], and G-CAM [GR]; n=10). All crowns were digitized with an intraoral scanner (CEREC Primescan SW 5.2) to generate their STL files (TC-STLs). MC-STL and TC-STLs were transferred into a 3-dimensional analysis software program (Medit Link v2.4.4), and a trueness (overall, external, occlusal, intaglio occlusal, and marginal) analysis was performed by using the root mean square (RMS) method. The Kruskal-Wallis and Dunn tests were performed to analyze data (?=.05). Results: The test groups had significantly different deviations on all surfaces (P?.001). MS crowns had higher overall (P?.007) and external surface (P?.001) deviations than GR and PMMA crowns, while the differences between GR and PMMA crowns were not significant (P?.441). BC crowns had higher external surface deviations than GR crowns (P=.005), higher occlusal deviations than GR and MS crowns (P?.007), and higher intaglio occlusal deviations than GR and MS crowns (P?.009). However, BC crowns had lower marginal deviations than MS and GR crowns (P?.018). Conclusions: The brand of resin-based CAD-CAM materials affected the trueness of crowns. Additively manufactured crowns (MS) mostly had lower overall and external surface trueness than the other groups. Nevertheless, the deviation values of occlusal, intaglio occlusal, and marginal trueness were generally small; thus, the effect of the tested materials on clinical crown fit may be negligible. © 2022 Editorial Council for the Journal of Prosthetic Dentistryen_US
dc.identifier.citationÇakmak, G., Rusa, A. M., Donmez, M. B., Akay, C., Kahveci, Ç., Schimmel, M., & Yilmaz, B. (2022). Trueness of crowns fabricated by using additively and subtractively manufactured resin-based CAD-CAM materials. The journal of prosthetic dentistry.en_US
dc.identifier.doi10.1016/j.prosdent.2022.10.012en_US
dc.identifier.issn0022-3913en_US
dc.identifier.scopus2-s2.0-85143159758en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.prosdent.2022.10.012
dc.identifier.urihttps://hdl.handle.net/20.500.12713/3794
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorDönmez, Mustafa Borga
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofThe Journal of Prosthetic Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleTrueness of crowns fabricated by using additively and subtractively manufactured resin-based CAD-CAM materialsen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
1-s2.0-S0022391322006904-main.pdf
Boyut:
2.11 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: