Increased acromiohumeral distance in a double-row arthroscopic rotator cuff surgery compared to a single-row surgery after 12 months

Yükleniyor...
Küçük Resim

Tarih

2021

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

BioMed Central Ltd

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

Background: Arthroscopic rotator cuff surgery is an effective treatment for rotator cuff tears with the considered use of double-row repair techniques becoming popular in the last decade. We aim to compare the effects of double- and single-row arthroscopic rotator cuff repairs (ARCR) on repair integrity (RI) and acromiohumeral distance (AHD). Methods: In this observational study, we retrospectively identified 98 patients with degenerative rotator cuff tear treated with arthroscopic rotator cuff repair between 2016 and 2019. We excluded 22 patients with partial-thickness tears, 15 with associated subscapularis or SLAP tears, 13 with massive tears, and 5 patients lost to follow-up; we included 43 patients who had ARCR for full-thickness cuff tear and clinical, radiologic follow-up. Of these 43 patients, 23 are grouped as double-row repair group (DRG) and 20 as single-row repair group (SRG). A minimum of 12 months after the surgery, bilateral shoulder MRIs were obtained. Contralateral shoulders without asymptomatic rotator cuff tears served as a control group (CG). The operating surgeon and two other surgeons experienced in arthroscopy blindly measured the AHD and determined the RI at the control MRIs in all groups. Functional assessments relied on UCLA and qDASH Scores. Results: The mean age was 57.89 (45–78) years, and the mean follow-up time was 28,65 (21–43) months. The mean AHD of the CG was 9.7 ± 0.96 mm, the preoperative AHD of DRG was 8.62 ± 1.45 mm, and SRG was 9.71 ± 0.95 mm. The postoperative mean AHD of DRG 9.61 ± 1.83 mm and SRG was 10.21 ± 1.97 mm. AHD differences between the preoperative and postoperative groups were significant (P=0.009). The increase of the AHD in the double-row group was significantly higher than the single-row group (P=0.004). There was a high correlation between the RI and DASH scores (P=0.005). RI did not correlate with the repair method (P=0.580). Conclusion: Although double-row repairs can maintain greater AHD than single-row repairs in the clinical setting, this difference did not affect functional results. Regardless of the surgical intervention, functional results are favourable if RI is achieved. Level of evidence: Level III, Retrospective Cohort Study.

Açıklama

Anahtar Kelimeler

Acromiohumeral Distance, Arthroscopy, Double-Row, Integrity, Rotator Cuff Repair, Single-Row

Kaynak

Journal of Orthopaedic Surgery and Research

WoS Q Değeri

Q3

Scopus Q Değeri

Q1

Cilt

16

Sayı

1

Künye

Turan, K., Çabuk, H., Köroğlu, C., & Öztürk, Ç. (2021). Increased acromiohumeral distance in a double-row arthroscopic rotator cuff surgery compared to a single-row surgery after 12 months. Journal of Orthopaedic Surgery and Research, 16(1), 1-7.