Effect of measurement techniques and operators on measured deviations in digital implant scans

dc.authoridMustafa Borga Dönmez / 0000-0002-3094-7487en_US
dc.authorscopusidMustafa Borga Dönmez / 57202022054en_US
dc.authorwosidMustafa Borga Dönmez / AGY-6155-2022en_US
dc.contributor.authorÇakmak, Gülce
dc.contributor.authorDönmez, Mustafa Borga
dc.contributor.authorAkay, Canan
dc.contributor.authorDe Silva, Marcella Paula
dc.contributor.authorMangano, F. G.
dc.contributor.authorAbou-Ayash, S.
dc.contributor.authorYılmaz, Burak
dc.date.accessioned2022-12-30T07:53:06Z
dc.date.available2022-12-30T07:53:06Z
dc.date.issued2022en_US
dc.departmentİstinye Üniversitesi, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.description.abstractObjectives: To evaluate the effect of different measurement techniques and operators on measured deviations in in vitro implant scans. Methods: A 2-piece system that comprises a healing abutment (HA) and a scan body (SB) was mounted onto an implant at right first molar site of a polymethylmethacrylate mandibular dentate model. Model was digitized by using an industrial scanner (reference model scan, n=1) and an intraoral scanner (test scan, n=20). All standard tessellation language files were imported into a 3-dimensional analysis software and superimposed. Three operators with similar experience performed circle-based and point-based deviation analyses (n=20). Deviations measured with different techniques were compared with paired samples t-test within each operator, while the reliability of the operators was assessed by using F-tests for both technqiues (?=.05). Results: Point-based technique resulted in lower deviations than circle-based technique for all operators (P=.001) with to higher reliability among operators (ICC=.438, P=.001). The correlation among the operators was nonsignificant when circle-based technique was used (ICC=.114, P=.189). Conclusion: Lower deviations were detected with the point-based technique. In addition, different operators' measurements had higher correlation when point-based technique was used compared with circle-based technique. Clinical significance: Point-based technique may be preferred over circle-based technique for research studies on scan accuracy of implants, given its higher reliability. The accuracy of measured deviations may increase if the number of planes are increased, which can facilitate point generation at different surfaces of the scan body.en_US
dc.identifier.citationÇakmak, G., Donmez, M. B., Akay, C., de Silva, M. P., Mangano, F. G., Abou-Ayash, S., & Yilmaz, B. (2022). Effect of measurement techniques and operators on measured deviations in digital implant scans. Journal of dentistry, 104388. Advance online publication. https://doi.org/10.1016/j.jdent.2022.104388en_US
dc.identifier.doi10.1016/j.jdent.2022.104388en_US
dc.identifier.pmid36502966en_US
dc.identifier.scopus2-s2.0-85146278526en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.urihttp://dx.doi.org/10.1016/j.jdent.2022.104388
dc.identifier.urihttps://hdl.handle.net/20.500.12713/3783
dc.identifier.wosWOS:000922160100001en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorDönmez, Mustafa Borga
dc.language.isoenen_US
dc.publisherELSEVIERen_US
dc.relation.ispartofJournal of dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDeviationen_US
dc.subjectDigital İmplant Scanen_US
dc.subjectMeasurement Techniqueen_US
dc.subjectOperatoren_US
dc.titleEffect of measurement techniques and operators on measured deviations in digital implant scansen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
1-s2.0-S0300571222004407-main.pdf
Boyut:
1.18 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: