3D-printed resin composite posterior fixed dental prosthesis: a prospective clinical trial up to 1 year

dc.authoridHobbi Paniz / 0009-0009-6551-3855
dc.authoridTuğçe Merve Ordueri / 0000-0002-7238-9102
dc.authoridFunda Öztürk Bozkurt / 0000-0001-7419-1071
dc.authoridTuğba Toz Akalın / 0000-0001-6427-3903
dc.authoridMuzaffer Ateş / 0000-0002-4394-0815
dc.authoridMutlu Özcan / 0000-0002-9623-6098
dc.authorscopusidTuğba Toz Akalın / 56563066500
dc.authorwosidTuğba Toz Akalın / KHG-6274-2024
dc.contributor.authorPaniz, Hobbi
dc.contributor.authorOrdueri, Tuğçe Merve
dc.contributor.authorÖztürk Bozkurt , Funda
dc.contributor.authorToz Akalın, Tuğba
dc.contributor.authorAteş, Muzaffer
dc.contributor.authorÖzcan, Mutlu
dc.date.accessioned2025-03-06T05:56:03Z
dc.date.available2025-03-06T05:56:03Z
dc.date.issued2024
dc.departmentİstinye Üniversitesi, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü
dc.description.abstractObjectives: This clinical trial evaluated the clinical behavior of 3D-printed posterior resin composite fixed dental prostheses (FDPs). Materials and methods: Between 10 October 2020 and 5 August 2022, 49 patients aged 19–60 years (16 men, 33 women) received 68 3D-printed resin composite 3-unit posterior FDPs (ELS Even Stronger, Saremco, Switzerland). FDPs were followed up 2 weeks after placement (baseline), 6 months after placement, and 1 year after placement by two independent calibrated observers using modified FDI criteria for anatomical form, secondary caries, marginal adaptation, surface roughness, color match, fracture of material, staining surface, staining margin, approximate anatomical form, retention, gingival health, and patient's view. Survival analyses were performed using Kaplan–Meier analyses. Results: A total of 59 restorations were evaluated and the mean observation period was 8.63 months. Failure types were categorized as mechanical and biological. Failures were observed in 14 FDPs. Nine FDPs showed mechanical failure and five FDPs showed biological failure. Mechanical failures were mostly experienced as connector fractures. Eight FDPs showed cohesive fractures (seven in a single connector at either at the mesial or distal and one in the pontic itself). Biological failures, including root canal treatment and gingival tissue reactions, were observed within the first 6 months. Based on mechanical failures, the survival rate was 86.7% including the biological complications; this corresponded to 71.6% (Kaplan–Meier). After 1 year, two FDPs showed surface luster loss (score 4), two-color mismatches (score 4), and two-surface staining (score 4). Conclusion: 3D-printed resin composite FDPs were observed acceptable after 1 year of clinical follow-up, providing that the experienced failure types were mainly associated with fractures in the connector region, which requires revision of design parameters. Clinical Trial Registration: Clinical Trials.Gov, NCT04600297. 2024 Hobbi, Ordueri, Öztürk-Bozkurt, Toz-Akalın, Ateş and Özcan.
dc.description.pubmedpublicationid39917685
dc.description.sponsorshipSaremco Dental AG
dc.identifier.citationHobbi, P., Ordueri, T. M., Öztürk-Bozkurt, F., Toz-Akalın, T., Ateş, M., & Özcan, M. (2024). 3D-printed resin composite posterior fixed dental prosthesis: a prospective clinical trial up to 1 year. Frontiers in Dental Medicine, 5, 1390600.
dc.identifier.doi10.3389/fdmed.2024.1390600
dc.identifier.endpage12
dc.identifier.issn2673-4915
dc.identifier.scopus2-s2.0-85196318824
dc.identifier.scopusqualityQ2
dc.identifier.startpage01
dc.identifier.urihttp://dx.doi.org/10.3389/fdmed.2024.1390600.
dc.identifier.urihttps://hdl.handle.net/20.500.12713/6000
dc.identifier.volume5
dc.identifier.wosWOS:001248705800001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakScopus
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakPubmed
dc.institutionauthorToz Akalın, Tuğba
dc.institutionauthoridTuğba Toz Akalın / 0000-0001-6427-3903
dc.language.isoen
dc.publisherFrontiers Media SA
dc.relation.ispartofFrontiers in Dental Medicine
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectSurvival
dc.subjectRestorative Materials
dc.subject3D-Printed Restoration
dc.subjectDental Materials
dc.subjectClinical Trial Composite 3-Unit Posterior FDPs
dc.subjectProsthodontics
dc.subjectPermanent Restorations
dc.title3D-printed resin composite posterior fixed dental prosthesis: a prospective clinical trial up to 1 year
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
fdmed-05-1390600.pdf
Boyut:
20.29 MB
Biçim:
Adobe Portable Document Format
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: