Effect of different surface treatments and thermomechanical aging on the ion elution of CAD-CAM materials

dc.authoridMustafa Borga Dönmez / 0000-0002-3094-7487en_US
dc.authorscopusidMustafa Borga Dönmez / 57202022054
dc.authorwosidMustafa Borga Dönmez / AGY-6155-2022en_US
dc.contributor.authorSert, Murat
dc.contributor.authorGülce Subaşı, Meryem
dc.contributor.authorÇakmak, Gülce
dc.contributor.authorDönmez, Mustafa Borga
dc.contributor.authorYılmaz, Burak
dc.date.accessioned2022-05-31T10:31:31Z
dc.date.available2022-05-31T10:31:31Z
dc.date.issued2022en_US
dc.departmentİstinye Üniversitesi, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.description.abstractStatement of problem. Dental ceramics have been reported to elute ions when subjected to nonneutral pH. However, the effect of surface treatments and thermomechanical aging on the ion elution of CAD-CAM ceramics is unclear. Purpose. The purpose of this in vitro study was to compare the effect of surface treatment (glazed or polished) and thermomechanical aging on the ion elution of CAD-CAM materials before and after 2-body wear simulation. Material and methods. Specimens were prepared from 6 CAD-CAM materialsdleucite (LC), feldspathic (FP), zirconia-reinforced lithium silicate (ZLS), lithium disilicate (LDS) glass-ceramics, polymer-infiltrated ceramic network (PICN), and zirconia (ZIR)dand divided into 2 groups according to the surface treatments (glazed or polished) (n=6). For baseline ion elution values, specimens were placed into polyethylene bottles containing deionized water (pH 7.4) that had been stored in an incubator for 168 hours at 37 C. The eluted ions in the immersion solution were measured by using inductively coupled plasma-optic emission spectrophotometry. The specimens were then subjected to thermomechanical aging by using human enamel as an antagonist. After aging, the ion elution of the specimens was remeasured. Ion elution data before and after 2-body wear were analyzed by using the Mann-Whitney U test, while the effect of 2-body wear was assessed by using the Wilcoxon signed rank test (a=.05). Results. The presence of some ions varied depending on the material-surface treatment pair before (Al, As, B, Ba, Ca, K, Li, Mg, Na, P, and Zn) and after (Al, B, Ba, Ca, Co, Li, Mg, and P) 2-body wear. Polished materials had higher ion elution than the glazed materials before 2-body wear (P .041), except for LC (P and Zn) and PICN (Ca, Cu, and K) (P .009). After 2-body wear, polished LC (B and Ba), FP (Al, B, and Mg), ZLS (Al, Ba, Ca, and Li), ZIR (B and Ba), glazed PICN (Ca, Mg, and P), ZLS (P), and ZIR (Co) presented higher ion elution than their counterparts (P .041). The effect of 2-body wear on the ion elution of polished LC (Al, K), FP (Na), ZLS (Li), LDS (K, Na), PICN (Al, Na), ZIR (Na, Y), glazed LC (Na), FP (Ba, Na), ZLS (B, Ba, Y), LDS (Na), PICN (Y), and ZIR (Na) was nonsignificant (P .075). However, the elution of remaining ions showed a significant difference before and after 2-body wear (P .046). Conclusions. The chemical stability of tested CAD-CAM materials was affected by the 2-body wear. Glazing led to a lower ion elution except for LDS and PICN. While polishing resulted in lower ion elution for PICN, both surface treatments resulted in similar ion elution for LDS. (J Prosthet Dent 2022;-:---)en_US
dc.identifier.citationSert M, Çakmak G, Subaşı MG, Donmez MB, Yilmaz B. Effect of different surface treatments and thermomechanical aging on the ion elution of CAD-CAM materials. J Prosthet Dent. 2022 Apr 28:S0022-3913(22)00202-5. doi: 10.1016/j.prosdent.2022.03.021. Epub ahead of print. PMID: 35491257.en_US
dc.identifier.doi10.1016/j.prosdent.2022.03.021en_US
dc.identifier.issn0022-3913en_US
dc.identifier.pmid35491257en_US
dc.identifier.scopus2-s2.0-85129818147en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.urihttp://doi.org/10.1016/j.prosdent.2022.03.021
dc.identifier.urihttps://hdl.handle.net/20.500.12713/2766
dc.identifier.wosWOS:000840261200017en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorDönmez, Mustafa Borga
dc.language.isoenen_US
dc.publisherElsevier Scienceen_US
dc.relation.ispartofThe Journal of Prosthetic Dentistyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleEffect of different surface treatments and thermomechanical aging on the ion elution of CAD-CAM materialsen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
1-s2.0-S0022391322002025-main.pdf
Boyut:
1.12 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: