Influence of digital implant analog design on the positional trueness of an analog in additively manufactured models: an in-vitro study

dc.authoridMustafa Borga Dönmez / 0000-0002-3094-7487en_US
dc.authorscopusidMustafa Borga Dönmez / 57202022054en_US
dc.authorwosidMustafa Borga Dönmez / AGY-6155-2022en_US
dc.contributor.authorMata-Mata, Severino J.
dc.contributor.authorDönmez, Mustafa Borga
dc.contributor.authorMeirelles, Luiz
dc.contributor.authorJohnston, William Michael
dc.contributor.authorYılmaz, Burak
dc.date.accessioned2022-11-08T14:01:04Z
dc.date.available2022-11-08T14:01:04Z
dc.date.issued2022en_US
dc.departmentİstinye Üniversitesi, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.description.abstractBackground: Limited evidence exists regarding the accuracy of implant analog position in printed models, particularly when implant analogs with varying designs are used. Purpose: To evaluate the effect of digital implant analog (DIA) design on the trueness of their position in additively manufactured digital implant models (DIMs) and to compare with that of a conventional implant analog in a stone cast. Materials and Methods: A dentate maxillary model with a conventional implant analog (Nobel Biocare Implant Replica 4.3 mm CC RP) at left second premolar site was digitized by using a laboratory scanner (3Shape D2000) and a (SB) scan body to generate the master standard tessellation language (STL) file (M0). 12 custom trays were fabricated on M0 file and conventional polyvinylsiloxane impressions of the model were made. All impressions were poured after inserting conventional implant analogs (Nobel RP Implant Replica) (Group A). Model was then digitized with an intraoral scanner (TRIOS 3) and the same SB, and DIMs with three different DIA designs (Nobel Biocare [Group B], Elos [Group C], and NT-trading [Group D]) were generated (Dental System-Model Builder). 12 DIMs of each design were additively manufactured and corresponding DIAs were inserted. All models were digitized by using the same laboratory scanner and SB, and these STLs were transferred to a 3D analysis software (Geomagic Control X), where the STL files of the models were superimposed over M0. Linear and 3D deviations at three selected points on SB (implant-abutment connection, most cervical point on SB, and most coronal point on SB) as well as angular deviations on two planes (buccolingual and mesiodistal) were calculated. Analysis of variance (ANOVA) and Bonferroni corrected t-tests were used to analyze the trueness of implant analog positions (? = 0.05). Results: The interaction of main effects significantly affected linear (p < 0.001) and angular deviations (p = 0.020). At point 1, group D had higher deviations than groups A and B (p ? 0.015). In addition, groups A and D had higher deviations than group B at point 4 (p < 0.001). While group C had similar linear deviations to those of other groups at point 1 and point 4 (p ? 0.192), the differences among test groups at point 2 were nonsignificant (p ? 0.276). Group B had lower angular deviations than groups C (p = 0.039) and D (p = 0.006) on buccolingual plane. Conclusions: Analog design affected the trueness of analog position as proprietary, pressure/friction fit DIA (group B) had higher linear trueness than screw-retained DIA (Group D) and conventional implant analog (group A). In addition, pressure/friction fit DIA had the highest angular trueness among tested DIAs.en_US
dc.identifier.citationMata-Mata, S. J., Donmez, M. B., Meirelles, L., Johnston, W. M., & Yilmaz, B. (2022). Influence of digital implant analog design on the positional trueness of an analog in additively manufactured models: An in-vitro study. Clinical Implant Dentistry and Related Research, doi:10.1111/cid.13137en_US
dc.identifier.doi10.1111/cid.13137en_US
dc.identifier.scopus2-s2.0-85139260807en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.urihttps://doi.org/10.1111/cid.13137
dc.identifier.urihttps://hdl.handle.net/20.500.12713/3301
dc.identifier.wosWOS:000863850000001en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorDönmez, Mustafa Borga
dc.language.isoenen_US
dc.publisherJohn Wiley and Sons Incen_US
dc.relation.ispartofClinical Implant Dentistry and Related Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAnalog Designen_US
dc.subjectDigital Dentistryen_US
dc.subjectDigital Implant Analogen_US
dc.subjectTruenessen_US
dc.titleInfluence of digital implant analog design on the positional trueness of an analog in additively manufactured models: an in-vitro studyen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
Clin Implant Dent Rel Res - 2022 - Mata‐Mata - Influence of digital implant analog design on the positional trueness of an.pdf
Boyut:
1.75 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: