Comparison of measured deviations in digital implant scans depending on software and operator
Yükleniyor...
Tarih
2022
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Elsevier
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
Objectives: To investigate the effect of 3-dimensional (3D) analysis software and operator on the measured deviations in implant scans. Material and Methods: A combined healing abutment-scan body (CHA-SB) system was digitized with an industrial scanner (ATOS Core 80) to generate a master standard tessellation language file (MRM-STL) and an intraoral scanner (TRIOS 3) to generate 9 test-scan STL files, which were transferred into metrology-grade (Geomagic Control X, GX and GOM Inspect, GM) and nonmetrology-grade (Medit Link, ML) software for deviation analysis. Test-scan STLs were superimposed over MRM-STL and 2 planes passing through the center of the SB were generated. Distance deviations at 8 points on these planes were analyzed by two different operators with similar level of experience. Data were analyzed with analysis of variance and F tests (?=.05). Results: Only model 1 (P=.049) analyzed by operator 2 showed significant differences among tested software, and the highest deviations were measured with GM (P?.037). However, the difference in values measured with GX and ML was nonsignificant (P=.91). Operator correlation was high (ICC?.712, P?.011), except for models 1 (GM, ICC=-.335, P=.813), 2 (GM, ICC=.025, P=.468 and ML, ICC=-.013, P=.507), 6 (GM, ICC=-.085, P=.583), and 8 (GM, ICC=-.386, P=.85). Conclusion: The measured deviations in implant scans in all models, except for one, were similar among the tested software, regardless of the operator. The inter-rater reliability of operators while using tested 3D analysis software was overall high. When observed, low inter-rater reliability was mostly with only one of the metrology grade software. Clinical Significance: Nonmetrology-grade 3D analysis software may be a suitable alternative to metrology-grade software to measure the deviations in digital implant scan body scans. When GOM metrology-software is used, measured deviations in implant scan body scans may vary more across operators. © 2022
Açıklama
Anahtar Kelimeler
Deviation, Implant, Scan, Scanbody, Software
Kaynak
Journal of Dentistry
WoS Q Değeri
Q1
Scopus Q Değeri
Q1
Cilt
122
Sayı
Künye
Cakmak, G., Marques, V. R., Donmez, M. B., Lu, W. -., Abou-Ayash, S., & Yilmaz, B. (2022). Comparison of measured deviations in digital implant scans depending on software and operator. Journal of Dentistry, 122 doi:10.1016/j.jdent.2022.104154