Comparison of measured deviations in digital implant scans depending on software and operator

dc.authoridMustafa Borga Dönmez / 0000-0002-3094-7487en_US
dc.authorscopusidMustafa Borga Dönmez / 57202022054en_US
dc.authorwosidMustafa Borga Dönmez / AGY-6155-2022
dc.contributor.authorÇakmak, Gülce
dc.contributor.authorMarques, Vinicius Rizzo
dc.contributor.authorDönmez, Mustafa Borga
dc.contributor.authorLu, Wei-En
dc.contributor.authorAbou-Ayash, Samir
dc.contributor.authorYılmaz, Burak
dc.date.accessioned2022-06-13T13:44:08Z
dc.date.available2022-06-13T13:44:08Z
dc.date.issued2022en_US
dc.departmentİstinye Üniversitesi, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.description.abstractObjectives: To investigate the effect of 3-dimensional (3D) analysis software and operator on the measured deviations in implant scans. Material and Methods: A combined healing abutment-scan body (CHA-SB) system was digitized with an industrial scanner (ATOS Core 80) to generate a master standard tessellation language file (MRM-STL) and an intraoral scanner (TRIOS 3) to generate 9 test-scan STL files, which were transferred into metrology-grade (Geomagic Control X, GX and GOM Inspect, GM) and nonmetrology-grade (Medit Link, ML) software for deviation analysis. Test-scan STLs were superimposed over MRM-STL and 2 planes passing through the center of the SB were generated. Distance deviations at 8 points on these planes were analyzed by two different operators with similar level of experience. Data were analyzed with analysis of variance and F tests (?=.05). Results: Only model 1 (P=.049) analyzed by operator 2 showed significant differences among tested software, and the highest deviations were measured with GM (P?.037). However, the difference in values measured with GX and ML was nonsignificant (P=.91). Operator correlation was high (ICC?.712, P?.011), except for models 1 (GM, ICC=-.335, P=.813), 2 (GM, ICC=.025, P=.468 and ML, ICC=-.013, P=.507), 6 (GM, ICC=-.085, P=.583), and 8 (GM, ICC=-.386, P=.85). Conclusion: The measured deviations in implant scans in all models, except for one, were similar among the tested software, regardless of the operator. The inter-rater reliability of operators while using tested 3D analysis software was overall high. When observed, low inter-rater reliability was mostly with only one of the metrology grade software. Clinical Significance: Nonmetrology-grade 3D analysis software may be a suitable alternative to metrology-grade software to measure the deviations in digital implant scan body scans. When GOM metrology-software is used, measured deviations in implant scan body scans may vary more across operators. © 2022en_US
dc.identifier.citationCakmak, G., Marques, V. R., Donmez, M. B., Lu, W. -., Abou-Ayash, S., & Yilmaz, B. (2022). Comparison of measured deviations in digital implant scans depending on software and operator. Journal of Dentistry, 122 doi:10.1016/j.jdent.2022.104154en_US
dc.identifier.doi10.1016/j.jdent.2022.104154en_US
dc.identifier.issn0300-5712en_US
dc.identifier.scopus2-s2.0-85131121487en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.urihttps://doi.org/10.1016/j.jdent.2022.104154
dc.identifier.urihttps://hdl.handle.net/20.500.12713/2881
dc.identifier.volume122en_US
dc.identifier.wosWOS:000807408300001en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.institutionauthorDönmez, Mustafa Borga
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofJournal of Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDeviationen_US
dc.subjectImplanten_US
dc.subjectScanen_US
dc.subjectScanbodyen_US
dc.subjectSoftwareen_US
dc.titleComparison of measured deviations in digital implant scans depending on software and operatoren_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
1-s2.0-S030057122200210X-main.pdf
Boyut:
16.71 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: