Comparison of the radiological parameters between dynamic-referencing tactile guidance robotic system and microplasty (r) instrumentation in unicompartmental knee arthroplasty
dc.authorid | Haluk Çabuk / 0000-0002-1413-2149 | en_US |
dc.authorid | Kaya Turan / 0000-0002-0547-995X | en_US |
dc.authorid | Osman Görkem Muratoğlu / 0000-0003-0049-7937 | en_US |
dc.authorid | Tuğrul Ergün / 0000-0002-5615-3394 | en_US |
dc.authorid | Çağatay Öztürk / 0000-0003-3133-206X | en_US |
dc.authorid | Ramazan Erden Ertürer / 0000-0003-4489-5937 | en_US |
dc.authorscopusid | Osman Görkem Muratoğlu / 57214073565 | |
dc.authorscopusid | Ramazan Erden Ertürer / 13104922500 | |
dc.authorscopusid | Haluk Çabuk / 56400866300 | |
dc.authorscopusid | Kaya Turan / 57201721233 | |
dc.authorscopusid | Tuğrul Ergün / 57480960700 | |
dc.authorscopusid | Çağatay Öztürk / 8230555600 | |
dc.authorwosid | Haluk Çabuk / AAL-9654-2020 | en_US |
dc.authorwosid | Kaya Turan / AGA-7891-2022 | en_US |
dc.authorwosid | Osman Görkem Muratoğlu / AGS-2887-2022 | en_US |
dc.authorwosid | Tuğrul Ergün / GPX-8467-2022 | en_US |
dc.authorwosid | Çağatay Öztürk / Y-7483-2018 | en_US |
dc.authorwosid | Ramazan Erden Ertürer / AAO-2634-2020 | en_US |
dc.contributor.author | Çabuk, Haluk | |
dc.contributor.author | Turan, Kaya | |
dc.contributor.author | Muratoğlu, Osman Görkem | |
dc.contributor.author | Ergün, Tuğrul | |
dc.contributor.author | Öztürk, Çağatay | |
dc.contributor.author | Ertürer, Ramazan Erden | |
dc.date.accessioned | 2022-11-12T07:24:33Z | |
dc.date.available | 2022-11-12T07:24:33Z | |
dc.date.issued | 2022 | en_US |
dc.department | İstinye Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü | en_US |
dc.description.abstract | Objectives: This study aims to compare the radiological outcomes of unicompartmental knee arthroplasty (UKA) performed by a navigation-based robotic system versus Microplasty (R) instrumentation. Patients and methods: Between January 2018 and January 2019, a total of 90 knees of 75 patients (65 males, 10 females; mean age: 62.0 +/- 9.4 years; range, 50 to 73 years) were included. Among these, 54 knees underwent Oxford mobile-bearing UKA with an Microplasty (R) instrumentation set and 36 knees were operated with the aid of a Restoris (R) MCK with MAKO navigation-based robotic system. Postoperative anteroposterior and lateral X-rays of all patients were evaluated according to nine different parameters. On the femoral side, femoral varus-valgus angle, flexion-extension angle, femoral condyle posterior fit; on tibial side, tibial component varus/valgus, tibial posterior slope, medial, anterior, posterior and lateral fit of tibial component assessed. Results: There was no significant difference between groups in terms of age, sex, and affected side. On the femoral side, no significant difference was observed in the component position between groups. On the tibial side, tibial component medial fit (p=0.032) and anterior fit (p=0.007) were better in navigation-based robotic system group. Conclusion: Microplasty (R) instrumentation may lead to comparable implant positioning compared to a tactile-based navigated robotic instrumentation. | en_US |
dc.identifier.doi | 10.52312/jdrs.2022.742 | en_US |
dc.identifier.issn | 2687-4784 | en_US |
dc.identifier.issn | 2687-4792 | en_US |
dc.identifier.scopus | 2-s2.0-85141810530 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.trdizinid | 1176323 | en_US |
dc.identifier.uri | http://dx.doi.org/10.52312/jdrs.2022.742 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12713/3352 | |
dc.identifier.wos | WOS:000876964500001 | en_US |
dc.identifier.wosquality | Q3 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.indekslendigikaynak | TR-Dizin | en_US |
dc.institutionauthor | Çabuk, Haluk | |
dc.institutionauthor | Turan, Kaya | |
dc.institutionauthor | Muratoğlu, Osman Görkem | |
dc.institutionauthor | Ergün, Tuğrul | |
dc.institutionauthor | Öztürk, Çağatay | |
dc.institutionauthor | Ertürer, Ramazan Erden | |
dc.language.iso | en | en_US |
dc.publisher | TURKISH JOINT DISEASES FOUNDATION | en_US |
dc.relation.ispartof | JOINT DISEASES AND RELATED SURGERY | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Component Alignment | en_US |
dc.subject | Microplasty? | en_US |
dc.subject | Navigation | en_US |
dc.subject | Robotics | en_US |
dc.subject | Unicompartmental Knee Arthroplasty | en_US |
dc.title | Comparison of the radiological parameters between dynamic-referencing tactile guidance robotic system and microplasty (r) instrumentation in unicompartmental knee arthroplasty | en_US |
dc.type | Article | en_US |