Comparison of the radiological parameters between dynamic-referencing tactile guidance robotic system and microplasty (r) instrumentation in unicompartmental knee arthroplasty

dc.authoridHaluk Çabuk / 0000-0002-1413-2149en_US
dc.authoridKaya Turan / 0000-0002-0547-995Xen_US
dc.authoridOsman Görkem Muratoğlu / 0000-0003-0049-7937en_US
dc.authoridTuğrul Ergün / 0000-0002-5615-3394en_US
dc.authoridÇağatay Öztürk / 0000-0003-3133-206Xen_US
dc.authoridRamazan Erden Ertürer / 0000-0003-4489-5937en_US
dc.authorscopusidOsman Görkem Muratoğlu / 57214073565
dc.authorscopusidRamazan Erden Ertürer / 13104922500
dc.authorscopusidHaluk Çabuk / 56400866300
dc.authorscopusidKaya Turan / 57201721233
dc.authorscopusidTuğrul Ergün / 57480960700
dc.authorscopusidÇağatay Öztürk / 8230555600
dc.authorwosidHaluk Çabuk / AAL-9654-2020en_US
dc.authorwosidKaya Turan / AGA-7891-2022en_US
dc.authorwosidOsman Görkem Muratoğlu / AGS-2887-2022en_US
dc.authorwosidTuğrul Ergün / GPX-8467-2022en_US
dc.authorwosidÇağatay Öztürk / Y-7483-2018en_US
dc.authorwosidRamazan Erden Ertürer / AAO-2634-2020en_US
dc.contributor.authorÇabuk, Haluk
dc.contributor.authorTuran, Kaya
dc.contributor.authorMuratoğlu, Osman Görkem
dc.contributor.authorErgün, Tuğrul
dc.contributor.authorÖztürk, Çağatay
dc.contributor.authorErtürer, Ramazan Erden
dc.date.accessioned2022-11-12T07:24:33Z
dc.date.available2022-11-12T07:24:33Z
dc.date.issued2022en_US
dc.departmentİstinye Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.description.abstractObjectives: This study aims to compare the radiological outcomes of unicompartmental knee arthroplasty (UKA) performed by a navigation-based robotic system versus Microplasty (R) instrumentation. Patients and methods: Between January 2018 and January 2019, a total of 90 knees of 75 patients (65 males, 10 females; mean age: 62.0 +/- 9.4 years; range, 50 to 73 years) were included. Among these, 54 knees underwent Oxford mobile-bearing UKA with an Microplasty (R) instrumentation set and 36 knees were operated with the aid of a Restoris (R) MCK with MAKO navigation-based robotic system. Postoperative anteroposterior and lateral X-rays of all patients were evaluated according to nine different parameters. On the femoral side, femoral varus-valgus angle, flexion-extension angle, femoral condyle posterior fit; on tibial side, tibial component varus/valgus, tibial posterior slope, medial, anterior, posterior and lateral fit of tibial component assessed. Results: There was no significant difference between groups in terms of age, sex, and affected side. On the femoral side, no significant difference was observed in the component position between groups. On the tibial side, tibial component medial fit (p=0.032) and anterior fit (p=0.007) were better in navigation-based robotic system group. Conclusion: Microplasty (R) instrumentation may lead to comparable implant positioning compared to a tactile-based navigated robotic instrumentation.en_US
dc.identifier.doi10.52312/jdrs.2022.742en_US
dc.identifier.issn2687-4784en_US
dc.identifier.issn2687-4792en_US
dc.identifier.scopus2-s2.0-85141810530en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.trdizinid1176323en_US
dc.identifier.urihttp://dx.doi.org/10.52312/jdrs.2022.742
dc.identifier.urihttps://hdl.handle.net/20.500.12713/3352
dc.identifier.wosWOS:000876964500001en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.indekslendigikaynakTR-Dizinen_US
dc.institutionauthorÇabuk, Haluk
dc.institutionauthorTuran, Kaya
dc.institutionauthorMuratoğlu, Osman Görkem
dc.institutionauthorErgün, Tuğrul
dc.institutionauthorÖztürk, Çağatay
dc.institutionauthorErtürer, Ramazan Erden
dc.language.isoenen_US
dc.publisherTURKISH JOINT DISEASES FOUNDATIONen_US
dc.relation.ispartofJOINT DISEASES AND RELATED SURGERYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectComponent Alignmenten_US
dc.subjectMicroplasty?en_US
dc.subjectNavigationen_US
dc.subjectRoboticsen_US
dc.subjectUnicompartmental Knee Arthroplastyen_US
dc.titleComparison of the radiological parameters between dynamic-referencing tactile guidance robotic system and microplasty (r) instrumentation in unicompartmental knee arthroplastyen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
2022-33-3-580-587-eng.pdf
Boyut:
596.13 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: